12
Recommended Operating Conditions
Supply voltages
Min.
Typ.
Max.
Unit
HV+
0
-
+95
V
+5 V
+4.75
+5.0
+5.2
V
Trigger input
Min.
Typ.
Max.
Unit
HIGH level input voltage
@ Zin=50
Ω
4.8
5
+5.2
V
LOW level input voltage
@ Zin=50
Ω
0
-
+0.8
V
Pulse width
1
2
100
µs
Repetition rate
-
-
200
kHz
Channel selection
Min.
Typ.
Max.
Unit
BIT0 / BIT1 input logic
high
+2.0
+5.0
+5.2
V
BIT0 / BIT1 input logic low +0.8
-
+0
V
Address transition time
-
-
1.0
MHz
Absolute maximum Ratings (destroying limits)
Supply voltages
Min.
Max.
Unit
HV+
0
+95
V
+5 V
0
+5.2
V
Trigger input
Min.
Max.
Unit
Trigger signal voltage,
unterminated
0
+5.2
V
Trigger Signal:
Note that the maximum ratings for both
pulse width and repetition rate depend
on the actual high voltage supply (HV). See section “Power Losses” for guidance.