background image

Page 7.3

HIGH DENSITY MATRIX MODULE 40-534/534A

pickering

SECTION 7 - MAINTENANCE INFORMATION

TABLE 7.1 - 40-534/534A Motherboard Relay Cross Reference 

Bank

Y

X

Relay Ref

Board

Bank

Y

X

Relay Ref

Board

1

1

1

1

Mother

1

3

1

65

Mother

1

1

2

2

Mother

1

3

2

66

Mother

1

1

3

3

Mother

1

3

3

67

Mother

1

1

4

4

Mother

1

3

4

68

Mother

1

1

5

5

Mother

1

3

5

69

Mother

1

1

6

6

Mother

1

3

6

70

Mother

1

1

7

7

Mother

1

3

7

71

Mother

1

1

8

8

Mother

1

3

8

72

Mother

1

1

9

9

Mother

1

3

9

73

Mother

1

1

10

10

Mother

1

3

10

74

Mother

1

1

11

11

Mother

1

3

11

75

Mother

1

1

12

12

Mother

1

3

12

76

Mother

1

1

13

13

Mother

1

3

13

77

Mother

1

1

14

14

Mother

1

3

14

78

Mother

1

1

15

15

Mother

1

3

15

79

Mother

1

1

16

16

Mother

1

3

16

80

Mother

1

1

17

17

Mother

1

3

17

81

Mother

1

1

18

18

Mother

1

3

18

82

Mother

1

1

19

19

Mother

1

3

19

83

Mother

1

1

20

20

Mother

1

3

20

84

Mother

1

1

21

21

Mother

1

3

21

85

Mother

1

1

22

22

Mother

1

3

22

86

Mother

1

1

23

23

Mother

1

3

23

87

Mother

1

1

24

24

Mother

1

3

24

88

Mother

1

1

25

25

Mother

1

3

25

89

Mother

1

1

26

26

Mother

1

3

26

90

Mother

1

1

27

27

Mother

1

3

27

91

Mother

1

1

28

28

Mother

1

3

28

92

Mother

1

1

29

29

Mother

1

3

29

93

Mother

1

1

30

30

Mother

1

3

30

94

Mother

1

1

31

31

Mother

1

3

31

95

Mother

1

1

32

32

Mother

1

3

32

96

Mother

1

2

1

33

Mother

1

4

1

97

Mother

1

2

2

34

Mother

1

4

2

98

Mother

1

2

3

35

Mother

1

4

3

99

Mother

1

2

4

36

Mother

1

4

4

100

Mother

1

2

5

37

Mother

1

4

5

101

Mother

1

2

6

38

Mother

1

4

6

102

Mother

1

2

7

39

Mother

1

4

7

103

Mother

1

2

8

40

Mother

1

4

8

104

Mother

1

2

9

41

Mother

1

4

9

105

Mother

1

2

10

42

Mother

1

4

10

106

Mother

1

2

11

43

Mother

1

4

11

107

Mother

1

2

12

44

Mother

1

4

12

108

Mother

1

2

13

45

Mother

1

4

13

109

Mother

1

2

14

46

Mother

1

4

14

110

Mother

1

2

15

47

Mother

1

4

15

111

Mother

1

2

16

48

Mother

1

4

16

112

Mother

1

2

17

49

Mother

1

4

17

113

Mother

1

2

18

50

Mother

1

4

18

114

Mother

1

2

19

51

Mother

1

4

19

115

Mother

1

2

20

52

Mother

1

4

20

116

Mother

1

2

21

53

Mother

1

4

21

117

Mother

1

2

22

54

Mother

1

4

22

118

Mother

1

2

23

55

Mother

1

4

23

119

Mother

1

2

24

56

Mother

1

4

24

120

Mother

1

2

25

57

Mother

1

4

25

121

Mother

1

2

26

58

Mother

1

4

26

122

Mother

1

2

27

59

Mother

1

4

27

123

Mother

1

2

28

60

Mother

1

4

28

124

Mother

1

2

29

61

Mother

1

4

29

125

Mother

1

2

30

62

Mother

1

4

30

126

Mother

1

2

31

63

Mother

1

4

31

127

Mother

1

2

32

64

Mother

1

4

32

128

Mother

Summary of Contents for 40-534

Page 1: ...uy your excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing R...

Page 2: ...pickeringtest com Issue 9 3 February 2020 40 534 534A User Manual PXI Ultra High Density Matrix Module...

Page 3: ...PICKERING INTERFACES ALL RIGHTS RESERVED No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Picker...

Page 4: ...ISO 14001 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment Pickering Interfaces aims to design and operate produ...

Page 5: ...ent instructions detailed within the product manual AVERTISSEMENT ATTENTION Des consignes de s curit appropri es doivent tre suivies En cas de danger potentiel existant prendre des pr cautions Consult...

Page 6: ...ction 3 Installation 3 1 Pre Operation Checks 3 1 Hardware Installation 3 1 Software Installation 3 3 Testing Operation 3 4 Section 4 Programming Guide 4 1 Programming Options For Pickering PXI Module...

Page 7: ...Page VI HIGH DENSITY MATRIX MODULE 40 534 534A pickering THIS PAGE INTENTIONALLY BLANK...

Page 8: ...sis PXI LXI sont peupl es d obturateurs pour emp cher l acc s aux signaux d E S utilisateur qui peuvent tre pr sents Les obturateurs sont disponibles sur commande chez Pickering dans une vari t de lar...

Page 9: ...imprim s PCB quip es de ces appareils doivent tre entrepos es et transport es dans des sacs antistatiques CAUTION PRODUCT DOCUMENTATION SYMBOL ATTENTION DOCUMENTATION PRODUIT Suitably qualified train...

Page 10: ...tching matrix constructed with reed relays The range is as follows 40 534A 021 Dual 32x4 matrix 1 pole or 1 pole screened 40 534A 022 Dual 32x4 matrix 2 pole Typical applications include signal routin...

Page 11: ...pactPCI Compliance The module is compliant with the PXI Specification 2 2 Local Bus Trigger Bus and Star Trigger are not implemented Uses a 33MHz 32 bit backplane interface Safety CE Compliance All mo...

Page 12: ...Mating Connectors Cabling For connection accessories for the 40 533A modules please refer to the 90 002D 200 pin LFH Connector Accessories data sheet where a complete list and documentation can be fou...

Page 13: ...cation Legacy and Hybrid Peripheral slots in a 3U PXI Express PXIe chassis Pickering Interfaces LXI or LXI USB Modular Chassis Chassis Selection Guide Standard PXI or hybrid PXIe Chassis from any Vend...

Page 14: ...o pickeringtest com software Signal Routing Software Our signal routing software Switch Path Manager automatically selects and energizes switch paths through Pickering switching systems Signal routing...

Page 15: ...Page 1 6 HIGH DENSITY MATRIX MODULE 40 534 534A pickering SECTION 1 TECHNICAL SPECIFICATION THIS PAGE INTENTIONALLY BLANK...

Page 16: ...le pole screened single pole or two pole relays depending on the module type The PCBs are connected via a ribbon cable for digital control signals and a socket for switch signals The relays are energi...

Page 17: ...Page 2 2 HIGH DENSITY MATRIX MODULE 40 534 534A pickering SECTION 2 TECHNICAL DESCRIPTION THIS PAGE INTENTIONALLY BLANK...

Page 18: ...et signalez imm diatement tout dommage Pickering Interfaces N essayez pas d installer le mat riel si des d g ts sont vidents 2 Placez le ch ssis contenant le module par rapport tout autre quipement qu...

Page 19: ...Pickering Interfaces modular LXI installation there is no requirement to use any particular power up sequence Le module doit tre install conform ment la proc dure suivante 1 Assurez vous que le syst m...

Page 20: ...he absence of LabVIEW the Runtime Engine is required to support the Pickering Test Panels application D abord installez les pilotes de la carte de commutation PXI de Pickering en ex cutant le programm...

Page 21: ...nt Panel GSFP using the desktop icon or via the Start menu Start Menu Pickering Interfaces Ltd General Soft Front Panel A selector panel will appear listing all installed Pickering PCI PXI or LXI swit...

Page 22: ...tion on the installation and use of drivers and the programming of Pickering s products in various software environments please refer to the Software User Manual This is available as a download from h...

Page 23: ...hitectures are shown in the diagrams below The two banks of the dual matrix are programmed as separate Sub Units 1 and 2 The following page gives some simple examples using the provided drivers the IV...

Page 24: ...edCards respectively VISA Driver Open with pipx40_init and close with pipx40_close Setting a Matrix Crosspoint Using the IVI driver Note the following example is for bank 1 of a dual matrix Bank 1 is...

Page 25: ...Page 4 4 HIGH DENSITY MATRIX MODULE 40 534 534A pickering SECTION 4 PROGRAMMING GUIDE THIS PAGE INTENTIONALLY BLANK...

Page 26: ...X114 X118 X118 X122 X122 X126 X126 X130 X130 X202 X202 X206 X206 X210 X210 X214 X214 X218 X218 X222 X222 X226 X226 X230 X230 Y102 Y102 Y202 Y202 X101 1 X101 2 X105 1 X105 2 X109 1 X109 2 X113 1 X113...

Page 27: ...114 1 X114 2 X118 1 X118 2 X122 1 X122 2 X126 1 X126 2 X130 1 X130 2 X202 1 X202 2 X206 1 X206 2 X210 1 X210 2 X214 1 X214 2 X218 1 X218 2 X222 1 X222 2 X226 1 X226 2 X230 1 X230 2 Y102 1 Y102 2 Y202...

Page 28: ...X224 2 X228 1 X228 2 X232 1 X232 2 Y104 1 Y104 2 Y204 1 Y204 2 GND X103 1 X103 2 X107 1 X107 2 X111 1 X111 2 X115 1 X115 2 X119 1 X119 2 X123 1 X123 2 X127 1 X127 2 X131 1 X131 2 X203 1 X203 2 X207 1...

Page 29: ...1 X109 1 X111 1 X113 1 X115 1 X117 1 X119 1 X121 1 X123 1 X125 1 X127 1 X129 1 X131 1 X201 1 X203 1 X205 1 X207 1 1 X209 1 X211 1 X213 1 X215 1 X217 1 X219 1 X221 1 X223 1 X225 1 X227 1 X229 1 X231 1...

Page 30: ...de l interface de commande distance Lorsque le syst me est sous tension et pendant le d marrage de Windows vous devriez vous attendre voir l activit p riodique sur l interface de commande distance RX...

Page 31: ...y some other application such as the Test Panels or Terminal Monitor Dans la section Informations VISA si VISA n est pas install cette absence sera signal e Cela n affecte pas le fonctionnement en uti...

Page 32: ...r s Pour les modules PXI qui sont pris en charge dans l un des ch ssis modulaire LXI de Pickering Interfaces comme le 60 102B et 60 103B aucune mise jour du logiciel du module n est n cessaire Si le m...

Page 33: ...ges suivantes fournissent une r f rence crois e entre les chemins de signaux du produit et des relais physiques sur le circuit imprim Les tables peuvent tre utilis es dans le processus de recherche de...

Page 34: ...91 Mother 1 1 28 28 Mother 1 3 28 92 Mother 1 1 29 29 Mother 1 3 29 93 Mother 1 1 30 30 Mother 1 3 30 94 Mother 1 1 31 31 Mother 1 3 31 95 Mother 1 1 32 32 Mother 1 3 32 96 Mother 1 2 1 33 Mother 1 4...

Page 35: ...2 1 28 128 Daughter 2 3 28 192 Daughter 2 1 29 129 Daughter 2 3 29 193 Daughter 2 1 30 130 Daughter 2 3 30 194 Daughter 2 1 31 131 Daughter 2 3 31 195 Daughter 2 1 32 132 Daughter 2 3 32 196 Daughter...

Page 36: ...RL122 RL123 RL124 RL125 RL126 RL127 RL128 Spare C101 C102 C103 C104 C105 U101 U102 U103 U104 U105 C106 C107 C108 C109 C110 U106 U107 U108 U109 U110 C111 C112 C113 C114 C115 U111 U112 U113 U114 U115 C...

Page 37: ...Page 7 6 HIGH DENSITY MATRIX MODULE 40 534 534A pickering SECTION 7 MAINTENANCE INFORMATION THIS PAGE INTENTIONALLY BLANK...

Page 38: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: