OPERATING AND INSTALLATION INSTRUCTIONS LBE 250 / LBE 500
PAGE 24
• In the menu Status memory the last 9 actions of the
control unit can be retrieved with the time stored.
• Automatic switching-off of the humidifieris deactivated
by
AutoStby active ‚Off‘.
Additionally, a number is now
shown in the expert menu under
AutoStby aktiv ‘off’
at
the bottom on the left, which shows the reason for the
AutoStby operation.
1 – No ventilation for 18 hours
2 – EEPROM
3 – Valve openings
4 – Switch
5 – Rinsing
• The external temperature sensor can be calibrated here.
• The menu guidance can be switched over from German
to English or to French and vice versa in the menu opti-
on Language.
• If the parameter
“Max. air humidity”
is set to
“On”
, the
air humidity setting in the customer´s menu is expanded
by the values 70 % an d 80 %.
This parameter must not be activated in an air
piping system, if it is integrated into the humi-
difier (condensation water may form in the
piping system!)
• In the menu
“Relative air humidity”
the humidity control
is switched from the absolute air humidity vontrol at 21
°C to relative air humidity control.
This parameter must not be activated in an air
piping system, if it is integrated into the humi-
difier (condensation water may form in the
piping system!)
• Here the temperature is set, to which the absolute humi-
dity control is related. The value can be set between 20
°C and 24 °C in 1-degree increments. This enables the
adjustment of the humidity control to the room tempe-
rature.
• When the parameter
“external Off”
is activated to
“On”
and if the contact is open at the external switching input,
the device is switched to the operating status “Control
Off”
(For more details, see Chapter 9.4)
. Air flow monito-
ring via the integrated microphone will still remain ac-
tive.
• Displays the parameterized device type. This setting can
only be adjusted in the factory defaults menu item.
1) CHANGE WATER
2) DESCALE
3) FLUSH
4) UV_CHECK
5) STANDBY
6) CALIBRATE UV
7) CALIBRATE AIR
8) START
9) START USER
0) STANDARD
Status memory
AutoStby activ
AutoStby activ On
4 Off <
Ext.Temp.Offset
+0.0
Ext.Temp.Offset
Language
English
German <
Max. air humidtiy 80 %
Max. air humidity On
Off <
Rel. air humidity
Rel. air humidity On
Off <
Temp.abs.humidity
Temp.abs.humidity
21 °C <
Ext. Off
Ext. Off On
Off <