PicC Electronics SMS Alert 9 User Manual Download Page 5

 

 

SMS Alert Alarm / Plus

 

 

Page 5 of 5  

How to operate the microphone to silently listen in  

 

You are able to phone the SMS Alert and listen in for noises within a 20m radius. Phone the SMS Alert and wait 
for it to auto answer. It will auto answer automatically after two rings. 

 

Siren 

 

If B is enabled (yellow LED on) and the unit is armed, the siren output relay will trigger for 1 minute and then 

reset. E.g. the siren will switch off (time-out) after 1 minute. 

 

General Definitions and advance information 

 
*Advanced settings should only be changed if really needed. 

 

To request the 
status of the SMS 

Alert at any given 

time, 

SMS 

1234 r 

or 

1234 R 

The SMS Alert will respond with, for example, the following: 

INPUT ON B- - 

- , #000 #87654321 

 

INPUT

          means:      - Inputs 1 to 8 are enabled or disabled (except input 

2)

 

# 87654321

   means:      - All inputs are on.  

# 00000001

   means:      - Input 1 is on and the rest are off. 

#ABC

            means:      - All relays are switched on. 

#A00

             means:      - Relay output A is switched on and the rest are off. 

B- - -             

means:      - Reports to one cellphone 

* Changing the 
security code 1234 

The default code is 1234 and can be changed through these steps: 
1.  SMS 

1234 04

 to the SMS Alert to enable it to change the code. 

2.  Send 

1234 CODE 

to the SMS Alert..The SMS Alert will SMS back: 

CODE ?

  

3.  You can now SMS your selected 4 digit numeric code, e.g. 5678. 
This code is used as a prefix to operate all commands.

 

Panic Input 

This input is always on and does not depend on the Key Switch. 

Key Input 

This input enables or disables the 8 inputs. The Key Input is on by default 

because of the red loop wire. 

E.g: A relay output can be used to arm and disarm the SMS Alert from 
another cellphone. 

Green LED 

Indicates when the SMS Alert is sending a SMS. The LED will stay on for 3 

seconds. 

If the light is flashing, a problem exists

. See troubleshooting. 

Yellow LED 

Indicates when B is active, e.g. the SMS Alert is now enabled. If 

B

 is the 

main user and it is off, then 

C

D

 and 

E

 won’t work even if it was 

programmed. 

Red LED 

Indicates when the 

Key input 

is enabled. When the red LED is on, all 8 

inputs are ready to be triggered. 

Input 2 is always enabled.

 

Triggering of inputs 

The inputs are triggered negatively by default. To change to 

negative 

remove

, SMS 

1234 03

. The SMS Alert will reset and power up again. This 

implies for 

Version 7.3 and up.

 

Missed Call function   

This is only applicable to input 1 and for user B (first user). The missed call 

function can be switched (toggled) on and off by sending: 

1234 01

 (this is 

Summary of Contents for SMS Alert 9

Page 1: ...ess control and monitoring etc SMS Alert 1 SMS Alert 1 works on the same principle than SMS Alert 9 but it is smaller and less expensive It is a programmable dual single input and 1 switched relay outputdevice The dimensions are approximately 155mm x 75mm x 55mm It reports tofour cellphones Input 1 Dual option Can be set to send a SMS on both aNegative apply or Negative remove trigger The SMS that...

Page 2: ...ser Manual SMS Alert Version 7 7 Input 1 ZONE 1 Input 2 ZONE 2 Input 3 ZONE 3 Input 4 ZONE 4 Input 5 ZONE 5 Input 6 ZONE 6 Input 7 ZONE 7 Input 8 ZONE 8 Input 9 Panic Features ARM DISARM STATUS LED SIREN OUTPUT RELAY OUTPUT ARM DISARM via KEY SWITCH or SMS ...

Page 3: ...There must be a space between 1234 and b 9 The SMS Alert will respond by sending its status back to you e g INPUT ON B 00000000000 Ensure that the character B appears in the SMS How to receive your first SMS 10 ARM Apply a positive pulse to the Key switch input for 50ms milliseconds and relay C will latch switch on or off to indicate that the SMS Alert is armed You will receive an ARMED SMS A pilo...

Page 4: ...SMS 1234 a off and the same for 1234 b off 1234 c off To switch all relays on SMS 1234 all on or else 1234 all off To pulse relay A SMS 1234 ap and the same for 1234 bp 1234 cp Programming the input SMS strings SMS characters You are able to programme the SMS messages you would like to receive on your cellphone s when your alarm goes off or when the inputs of the SMS Alert are triggered Each input...

Page 5: ...ert to enable it to change the code 2 Send 1234 CODE to the SMS Alert The SMS Alert will SMS back CODE 3 You can now SMS your selected 4 digit numeric code e g 5678 This code is used as a prefix to operate all commands 3 Panic Input This input is always on and does not depend on the Key Switch 4 Key Input This input enables or disables the 8 inputs The Key Input is on by default because of the red...

Page 6: ...sted in South Africa only Technical Specifications 1 Power supply Minimum of 12 volt DC 500mA milliamps Standby is 30 50 mA You must at least have a battery pack inline Auxiliary outputs on panels do not provide sufficient power 2 Number of cellphone users 1 4 3 Relay contacts 5A Use additional external relays for more current It is not recommended to run 220 V through the relays 4 Inputs 1 to 8 T...

Page 7: ...rial touching wires No wires must touch the aerial of the phone The SMS Alert won t work inside a metal container Use our magnetic external extension aerials for weak reception 4 Insert SIM card error Remove the SIM card and slightly twist the SIM card contacts more upward with a small screwdriver 5 Other equipment used in conjunction with SMS Alert It is not recommended that other receivers trans...

Page 8: ...MS Alert report to the 1st phone toggle 1234 C Report to 2nd phone toggle 1234 D Report to 3rd phone toggle 1234 E Report to 4th phone toggle 1234 R To request the status of the SMS Alert 1234 A ON To switch relay A on and the same for B and C 1234 A OFF To switch relay A off and the same for B and C 1234 AP Pulse Relay A once for 500ms and the same for B and C 1234 APP Pulse Relay A 10 times Pepp...