background image

 

 

SMS Alert Alarm / Plus

 

 

Page 4 of 4  

How to program the SMS Alert to report to a 2

nd

, 3

rd

 or 4

th

 cellphone 

 

If you want the SMS Alert to report to a 2

nd

 cellphone, send 

1234

 and then the character 

c

 from a second 

cellphone to the SMS Alert. To turn this feature 

off

, SMS 

1234 

again and then the character 

from the second 

cellphone. 

E.g:  1234 c 

(There 

must be a space

 between 

1234

 and 

c

. Do the same for 

1234 d 

(3

rd

), and 

1234 e 

(4

th

).

 

 

How to operate the relay outputs 

 

The three outputs can be used for anything that requires remote controlling, for example to switch machinery 

and equipment on and off or to open and close it, or to switch your alarm on and off.

 

 

SMS 

1234 

and the 

command

 to switch the relay outputs. 

 

E.g:  1234 a on. 

There

 must be one space

 between 

1234

 and 

a

 and 

on,

 or 

1234

 and 

A

 and 

ON.

 

To switch relay A on, SMS:   

1234 a on

,  

and the same for  

   

1234 b on, 1234 c on

 

To switch relay A off, SMS:   

1234 a off

,  

and the same for  

   

1234 b off, 1234 c off

 

To switch 

all

 relays on, SMS:  

1234 all on

,   or else   

    

   

1234 all off

 

To pulse relay A, SMS:   

1234 ap

,  

and the same for 

   

1234 bp

1234 cp

 

 

Programming the input SMS strings (SMS characters):         

 

You are able to programme the SMS messages you would like to receive on your cellphone/s when your alarm 
goes off or when the inputs of the SMS Alert are triggered. Each input sends a different SMS to your 

cellphone/s. Input one is usually connected to a siren through an interface relay. Input two is usually connected 

to an alarm receiver so that it SMS you arm/disarm.

 

 

Important: Strings must not be longer than 20 characters, including spaces, commas, etc.

 

 

Example: 

If you want Input 1 to SMS you  “

John’s room !

” when the alarm is triggered: 

 

 

1.  SMS 

1234 1

 (One space between 4 and 1 and no space afterwards)  

2.  You get the following SMS back: 

Str 1 ?

 

3.  SMS “

John’s room !

” ,  

4.  You get back a SMS 

Str1 OK. 

Do not include 1234! 

 

 

Input 1 : 1234 1 

 

Input 2 : 1234 2 

 

Input 3 : 1234 3 

 

Input 4 : 1234 4 

 

Input 5 : 1234 5 

 

Input 6 : 1234 6 

 

Input 7 : 1234 7  

 

Input 8 : 1234 8 

 

Input 9 : Panic (not programmable) 

 

 

 

Summary of Contents for SMS Alert 9

Page 1: ...ess control and monitoring etc SMS Alert 1 SMS Alert 1 works on the same principle than SMS Alert 9 but it is smaller and less expensive It is a programmable dual single input and 1 switched relay outputdevice The dimensions are approximately 155mm x 75mm x 55mm It reports tofour cellphones Input 1 Dual option Can be set to send a SMS on both aNegative apply or Negative remove trigger The SMS that...

Page 2: ...ser Manual SMS Alert Version 7 7 Input 1 ZONE 1 Input 2 ZONE 2 Input 3 ZONE 3 Input 4 ZONE 4 Input 5 ZONE 5 Input 6 ZONE 6 Input 7 ZONE 7 Input 8 ZONE 8 Input 9 Panic Features ARM DISARM STATUS LED SIREN OUTPUT RELAY OUTPUT ARM DISARM via KEY SWITCH or SMS ...

Page 3: ...There must be a space between 1234 and b 9 The SMS Alert will respond by sending its status back to you e g INPUT ON B 00000000000 Ensure that the character B appears in the SMS How to receive your first SMS 10 ARM Apply a positive pulse to the Key switch input for 50ms milliseconds and relay C will latch switch on or off to indicate that the SMS Alert is armed You will receive an ARMED SMS A pilo...

Page 4: ...SMS 1234 a off and the same for 1234 b off 1234 c off To switch all relays on SMS 1234 all on or else 1234 all off To pulse relay A SMS 1234 ap and the same for 1234 bp 1234 cp Programming the input SMS strings SMS characters You are able to programme the SMS messages you would like to receive on your cellphone s when your alarm goes off or when the inputs of the SMS Alert are triggered Each input...

Page 5: ...ert to enable it to change the code 2 Send 1234 CODE to the SMS Alert The SMS Alert will SMS back CODE 3 You can now SMS your selected 4 digit numeric code e g 5678 This code is used as a prefix to operate all commands 3 Panic Input This input is always on and does not depend on the Key Switch 4 Key Input This input enables or disables the 8 inputs The Key Input is on by default because of the red...

Page 6: ...sted in South Africa only Technical Specifications 1 Power supply Minimum of 12 volt DC 500mA milliamps Standby is 30 50 mA You must at least have a battery pack inline Auxiliary outputs on panels do not provide sufficient power 2 Number of cellphone users 1 4 3 Relay contacts 5A Use additional external relays for more current It is not recommended to run 220 V through the relays 4 Inputs 1 to 8 T...

Page 7: ...rial touching wires No wires must touch the aerial of the phone The SMS Alert won t work inside a metal container Use our magnetic external extension aerials for weak reception 4 Insert SIM card error Remove the SIM card and slightly twist the SIM card contacts more upward with a small screwdriver 5 Other equipment used in conjunction with SMS Alert It is not recommended that other receivers trans...

Page 8: ...MS Alert report to the 1st phone toggle 1234 C Report to 2nd phone toggle 1234 D Report to 3rd phone toggle 1234 E Report to 4th phone toggle 1234 R To request the status of the SMS Alert 1234 A ON To switch relay A on and the same for B and C 1234 A OFF To switch relay A off and the same for B and C 1234 AP Pulse Relay A once for 500ms and the same for B and C 1234 APP Pulse Relay A 10 times Pepp...

Reviews: