REMOVING AND REPLACEMENT THE HEATING
UNIT
55
By default, Designer XL is equipped with a heating unit 400. It is designed to print using
most materials at operating temperatures of up to 410 ºC. There is no need to remove the
heater after each printing.
Remove it in the following cases:
To remove, install or replace the heating unit, follow the step-by-step instructions:
Before printing using PLA, PETG, and flexible materials from certain
manufacturers, when you need to replace «unit 400» for «unit 250».
If there is any visible or hidden damage to the heater, which impedes the
filament flow or results in an improper operation of the heater. In this case, you
shall replace the heater with a new one.
When the feed channel is clogged, so that nozzle replacement does not help,
remove the heating unit and clean the channel manually.
Unload the filament through the menu «Filament > Unload filament».
Set the printer power button to 0. The printer turns off.
Move the printhead towards yourself.
Unscrew the 2 screws on the upper PH cover and remove the PH upper cover towards
yourself.
1.
2.
3.
4.