PianoDisc ProRecord Installation Procedure With Troubleshooting Manual Download Page 5

o

 

Find the best location for the sensors on each pedal that is out of sight and best place for the least 
amount of damage. 

o

 

Mount each sensor with 2 screws. 

o

 

Place a piece of reflective tape under each sensor. 

o

 

Adjust the sensor to so the spacer tab just touches the lever. 

o

 

Note that the pedal sensors need to be place so the lever 

moves away 

from the sensor. 

o

 

Note that Ill. 9 shows a soft shift sensor that was mounted inside the action cavity.  This was 
done because there was no room to mount on the underside of the keybed. 

o

 

Tie up and route the cables to the control unit. 

 

                          

 

 
                                             Ill. 9 – Soft shift sensor 

 

                           

                           

 

 
                            

 Illustration 10 – Sostenuto pedal sensor 

 
 

Summary of Contents for ProRecord

Page 1: ...eys 2 Placing reflective tape on keys 1 and 88 NOTE The following procedure is the same whether a grand or vertical o Locate the reflective tape and paper jig in the kit o Starting with key 1 and 88 place the template on the front bottom of the key and attach the reflective tape Do this on both keys See Ill 1 Note Because keys 1 88 are wider than other white keys the reflective tape is place on on...

Page 2: ...ross the end of all keys to simulate how the keys will be in the piano See Ill 3 o Place the ruler across the bottom of the keys at the front of the reflective tape and draw a line across all keys See Ill 4 o Now place the reflective tape on all keys at the line just established Ill 2 Supporting keys Ill 3 Line up keys Ill 4 Marking line from Key 1 to 88 ...

Page 3: ...up so there is no gap and the tool can slide out without resistance o Do this to all mounting locations See Ill 5 o If the key is being held up by the spacer tool then the keyframe must be cut to lower the sensor strip the required amount If this is necessary go to the section Cutting Keyframe NOTE The spacer should just be able to slide out when the key is at full depression This will provide the...

Page 4: ... recommends using a Drill Press Planer seen in illustration 8 There are other methods to remove wood but this is easy and precise o Here is a link to Wood Workers Supply where it can be purchased http woodworker com fullpres asp PARTNUM 24760 LARGEVIEW ON Illustration 8 Cutting keyframe with drill press planer 5 Pedal Sensor Installation The pedal sensors are optical also and sense all three pedal...

Page 5: ...the sensor to so the spacer tab just touches the lever o Note that the pedal sensors need to be place so the lever moves away from the sensor o Note that Ill 9 shows a soft shift sensor that was mounted inside the action cavity This was done because there was no room to mount on the underside of the keybed o Tie up and route the cables to the control unit Ill 9 Soft shift sensor Illustration 10 So...

Page 6: ...Illustration 11 Sustain pedal sensor 6 Cable connections ...

Page 7: ...keybed o Mount the control box to the keybed o If a PianoDisc player system is installed use the PianoDisc ProRecord cable connected between the TFT Record port of the PianoDisc CPU unit and the EXT port of the ProRecord unit The EXT port is located on the right side of the ProRecord control unit see right side drawing on the next page o If a PianoDisc is NOT installed use the 9VAC adapter on the ...

Page 8: ...Right Side of Control Unit PianoDisc CPU unit Front of the Control Unit ...

Page 9: ...done again o It may be helpful to pause a moment between each note to ensure that the note calibrates properly o If any key or pedal did not calibrate properly setup cannot be completed until the keys and or pedals have been calibrated The system will play the MIDI note of the keys or pedals that need to be calibrated Play the keys or pedals again and then push PLAY If the problem is with one of t...

Page 10: ...on In Out CPU PianoDisc PianoDisc ProRecord cable USB MIDI Interface Cable Roland Apple USB camera adapter selector switch in TAB posistion iDevice EXT ProRecord Control Box For record and playback iDevice wiring diagram with PianoDisc o Use the following wiring diagram for iDevices without PianoDisc o A lightning to 30 pin adapter may be needed depending on the i device version ...

Page 11: ...gram without PianoDisc o Use the following wiring diagram for recording to a computer In Out CPU PianoDisc PianoDisc ProRecord cable Computer USB MIDI Interface Cable Roland selector switch in COMP posistion For record and playback Computer wiring diagram with PianoDisc ProRecord Control Box EXT o Use the following wiring diagram to connect a Computer without PianoDisc ...

Page 12: ...ord and playback Computer wiring diagram without PianoDisc o Use the following diagram to connect to a computer for recording only ProRecord Control Box USB Computer USB mini USB cable Computer USB connection record only o Use the following connection to connect to a MIDI device MIDI keyboard or sound generator ...

Page 13: ...ProRecord Control Box OUT IN IN OUT Standard MIDI Cables MIDI Device Connecting to MIDI device Cables PianoDisc ProRecord Cable Roland USB MIDI interface cable ...

Page 14: ...To check this you would need to unplug the cable and do a continuity test See the pin out diagram below This will require a volt meter Problem The system will not complete the calibration 1 Check all plug connections carefully 2 During calibration depress each key completely before depressing the next key If keys overlap it will not calibrate 3 Make sure the pedal sensors are installed correctly T...

Page 15: ...ded by a laptop iPad to the CPU thru the iQ stereo mini port Just need to unplug the Mini cable from the Airport Express and plug into the laptop iPad The software can be send thru e mail 5 It is possible to have a bad record cable which goes from the ProRecord control box to the iQ CPU Try another record cable 6 To check the output of the ProRecord control box A Unplug the record cable from the E...

Page 16: ...and ProScan Sensor Strip Repair The ProRecord and ProScan sensor strips can be replaced in the field in most cases 1 Damaged section A A damaged section can be easily replaced by the technician instead of shipping back the complete strip This will minimize the potential damage caused by shipping the complete strip B There are 4 sections to a sensor strip The two center sections are identical but t...

Page 17: ......