Problem: Pedal or Pedals will not record.
1.
Make sure the pedal lever is moving away for the sensor.
2.
Check the alignment of the sensor to the lever.
3.
Make sure there is reflective tape on the lever and aligned to the sensor.
4.
Move the sensor 1/8” away from the lever and re-calibrate.
5.
Make sure the sensor cables are on the correct sensor. (For example – sustain cable on sustain
lever)
6.
Perform pin out continuity check on cable. See below.
ProRecord and ProScan Sensor Strip Repair
The ProRecord and ProScan sensor strips can be replaced in the field, in most cases.
1.
Damaged section
A.
A damaged section can be easily replaced by the technician instead of shipping back the
complete strip. This will minimize the potential damage caused by shipping the complete
strip.
B.
There are 4 sections to a sensor strip. The two center sections are identical but the two end
sections are unique. (See pictures below)
C.
Each section is secured with two screws. There is a plug connection that connects each
board to the next. See the pictures below how the plug connection folds over to connect the
neighboring board.