- Ripristinare il livello liquido freni in vaschetta.
In caso di necessità è possibile eseguire lo spurgo anche mediante pompa a depressione specifica
THE BLEEDING OPERATIONS OF THE BRAKING SYSTEM, EVEN FOR THE VERSION EQUIPPED
WITH ABS SYSTEM, DO NOT ALLOW THE USE OF DIAGNOSTIC TESTER, AND ARE THERE-
FORE EQUAL TO THOSE DESCRIBED FOR THE STANDARD BRAKE SYSTEM.
N.B.
DURING THE BLEEDING OPERATIONS, MAKE SURE THE BRAKE FLUID DOES NOT COME INTO
CONTACT WITH THE BODYWORK SO AS NOT TO DAMAGE IT. FURTHERMORE, DURING THE
BLEEDING OPERATIONS REGARDING THE BRAKE CALLIPERS, MAKE SURE THE BRAKE
FLUID DOES NOT COME INTO CONTACT WITH THE DISC BRAKES AND WITH THE BRAKE
PADS. FAILURE TO OBSERVE THIS PRECAUTION WILL ENDANGER THE PROPER WORKING
AND EFFICIENCY OF THE BRAKING SYSTEM
Specific tooling
020329Y
Mity-Vac vacuum-operated pump
Locking torques (N*m)
Oil bleed screw
12 - 16
Refitting
- Al rimontaggio eseguire l'operazione in senso inverso.
- Bloccare la tubazione idraulica alla coppia prescritta ed effettuare lo spurgo dell'impianto.
Ad operazione conclusa serrare la vite di spurgo olio alla coppia prescritta.
N.B.
WHILE REFITTING, REPLACE THE COPPER GASKETS ON THEIR FITTINGS.
WARNING
BRAKE FLUID IS HYGROSCOPIC; THAT IS, IT ABSORBS MOISTURE FROM THE SURROUND-
ING AIR. IF THE LEVEL OF MOISTURE IN THE FLUID EXCEEDS A GIVEN VALUE, BRAKING WILL
BE INEFFICIENT. THEREFORE, ALWAYS USE FLUID FROM SEALED CONTAINERS. UNDER
NORMAL DRIVING AND CLIMATIC CONDITIONS YOU SHOULD CHANGE THIS FLUID EVERY
TWO YEARS. IF BRAKES ARE USED INTENSELY AND/OR IN HARSH CONDITIONS, CHANGE
THE FLUID MORE FREQUENTLY.
CAUTION
WHEN CARRYING OUT THE OPERATION, BRAKE FLUID MAY LEAK FROM BETWEEN THE
BLEED SCREW AND ITS SEAT ON THE CALLIPER. CAREFULLY DRY THE CALLIPER AND DE-
GREASE THE DISC SHOULD THERE BE BRAKE FLUID ON IT.
Locking torques (N*m)
Oil bleed screw
12 - 16
Raccordo olio pompa-tubo
13÷18
Fixing screws for the handlebar control
unit U-bolts
7 ÷ 10
See also
Front
Refitting
- Al rimontaggio eseguire l'operazione in senso inverso.
- Bloccare la tubazione idraulica alla coppia prescritta ed effettuare lo spurgo dell'impianto.
MSS X10 500ie Executive
Braking system
BRAK SYS - 181
Summary of Contents for MSS X10 500ie Executive
Page 1: ...SERVICE STATION MANUAL 677654 EN MSS X10 500ie Executive...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR...
Page 14: ...INDEX OF TOPICS TOOLING TOOL...
Page 25: ...INDEX OF TOPICS MAINTENANCE MAIN...
Page 36: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL...
Page 38: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS...
Page 42: ...Components arrangement Electrical system MSS X10 500ie Executive ELE SYS 42...
Page 109: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE...
Page 117: ...INDEX OF TOPICS ENGINE ENG...
Page 126: ...INDEX OF TOPICS INJECTION INJEC...
Page 139: ...INDEX OF TOPICS SUSPENSIONS SUSP...
Page 175: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS...
Page 190: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS...
Page 198: ...Cooling system fluid 1 75 l Cooling system MSS X10 500ie Executive COOL SYS 198...
Page 199: ...INDEX OF TOPICS CHASSIS CHAS...
Page 222: ...INDEX OF TOPICS PRE DELIVERY PRE DE...
Page 226: ...V Vehicle 7 110 113...