11 - 3
11
Cooling
SPECIFICATIONS
Cooling system capacity
1.8 l
Recommended fluid
50% mixture of water and sealed circuit fluid (PARAFLU 11 FE)
Seal pressure
Plug calibrated to 0.9 bar
THERMOSTAT
Type
wax, with switch
Initial opening
75 ± 2 °C
Opening stroke at 90° C
4 mm
ELECTROVENTILATION
Type
injection operated
Initial electroventilation
106° C
End electroventilation
98° C
WATER PUMP
Type
centrifuge
Command
coaxial to the counter shaft
RADIATOR
Type
in aluminium with horizontal circulation
EXPANSION TANK
Type
self-discharging, parallel to the
radiator