User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 14 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
Discharging the P-603
The P-603 must be discharged in the following cases:
Before installation
When the P-603 is not in use but the electronics remains switched on to ensure
temperature stability
Before demounting (e.g., before cleaning and transporting the P-603 and for
modifications)
If the connecting cable of the P-603 is accidentally disconnected from the electronics
during operation
Requirements
You have read and understood the safety precautions (p. 6).
Tools and accessories
If the P-603 is
not
connected to the electronics:
Only for P-603
without
connector:
10 kΩ discharge resistor (not included in scope of delivery), the
touchable parts must be
adequately insulated for the actuator's operating voltage range (p. 17)
Only for P-603
with
connector:
Electronics from PI
Discharging a P-603 connected to the electronics
Set the piezo voltage to 0 V on the electronics.
Discharging a P-603 not connected to the electronics
If the P-603 does
not
have a connector:
1.
Ensure adequate protection against touching live parts.
2.
Short-circuit the stranded wires of the P-603 for at least a few seconds using a
10 kΩ
discharge resistor
.
If the P-603 has a connector:
Connect the voltage connector of the P-603 to the
switched off
PI electronics, which
have an internal discharge resistor, for at least a few seconds.
Maintenance
The P-603 is maintenance-free.