PI P-603 Series User Manual Download Page 11

User Manual 

P603T0001, valid for P-603 

CBo, 1/11/2021 

 

 

 

Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany 

Page 11 / 21 

Phone +49 721 4846-0, Fax +49 721 4846-1019, Email 

[email protected]

, 

www.pi.ws

 

Unpacking 

 

NOTICE 

 

Damage due to pull forces on the connecting cable or stranded wires! 

Pull forces on the connecting cable or stranded wires can damage the P-603. 

 

Avoid pull forces on the connecting cable or stranded wires. 

 

 

NOTICE 

 

Destruction of the piezo actuator due to contamination! 

Contamination on the surface of the piezo actuator of the P-603 can result in the destruction of 

the piezo actuator by electric flashovers during operation. 

 

When handling the P-603, wear powder-free nitrile or latex gloves. 

 

Prevent the P-603 from coming into contact with conductive liquids (e.g., finger sweat) and 

conductive materials (e.g., metal dust). 

 

If the piezo actuator of the P-603 has been accidentally contaminated, contact our 

customer service department (p. 15). 

 

 

NOTICE 

 

Destruction of the piezo actuator by mechanical overload! 

Mechanical forces can damage the piezo actuator of the P-603. 

 

Avoid impacts that affect the P-603. 

 

Do 

not

 drop the P-603. 

 

Unpacking the P-603 

1.

 

Unpack the P-603 with care. 

2.

 

Compare the contents with the scope of delivery according to the contract and the 

delivery note. 

3.

 

Inspect the contents for signs of damage. If any parts are damaged or missing, contact 

our customer service department immediately. 

4.

 

Keep all packaging materials in case the product needs to be returned. 

 

Summary of Contents for P-603 Series

Page 1: ...valid for P 603 CBo 1 11 2021 Physik Instrumente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws P 603 Inexpensive Pie...

Page 2: ...Use 5 Safety Precautions 6 Electrical Dangers 6 Mechanical Dangers 8 Thermal Dangers 9 Product Description 9 Model Overview 9 Product View 10 Scope of Delivery 10 Suitable Electronics 10 Unpacking 11...

Page 3: ...mente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Page 3 21 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws Maximum Ratings 17 Ambient Conditions and Classificati...

Page 4: ...nventions are used in this user manual CAUTION Dangerous situation Failure to comply could lead to minor injury or cause damage to equipment Precautionary measures for avoiding NOTICE Dangerous situat...

Page 5: ...ing Contact our customer service department p 15 Downloading manuals 1 Open the website www pi ws 2 Search the website for the product number e g P 603 or the product family e g PiezoMove 3 Click the...

Page 6: ...able to read out and process the signals from the position sensors For information about the electronics refer to their separate documentation p 5 Safety Precautions Electrical Dangers CAUTION Dangero...

Page 7: ...g for modifications reconnect the overall system to the protective earth conductor before starting it up again NOTICE Destruction of the piezo actuator by electric flashovers The use of the P 603 in...

Page 8: ...x Do not exceed the maximum push force of 30 N on the moving part Do not exceed the maximum pull force of 10 N on the moving part In dynamic operation take special care not to exceed the maximum push...

Page 9: ...ics before reconnecting Thermal Dangers CAUTION Burning from hot surface The surface of the P 603 and the surrounding area can heat up during operation Touching the P 603 and surrounding parts can res...

Page 10: ...actuator according to order p 9 P603T0001 User manual for P 603 this document Suitable Electronics Product number Description Suitability E 610 Piezo amplifier servo controller All P 603 models E 625...

Page 11: ...ration When handling the P 603 wear powder free nitrile or latex gloves Prevent the P 603 from coming into contact with conductive liquids e g finger sweat and conductive materials e g metal dust If t...

Page 12: ...electrically insulated according to protection class II When you choose the first or the second option 1 Pay attention to the applicable standards for mounting the protective earth conductor 2 Make su...

Page 13: ...ness of the surface is 40 m You have discharged the P 603 p 14 Tools and accessories Two M2 5 screws of suitable length p 19 for mounting the actuator onto a surface Two M2 5 screws of suitable length...

Page 14: ...and accessories If the P 603 is not connected to the electronics Only for P 603 without connector 10 k discharge resistor not included in scope of delivery the touchable parts must be adequately insul...

Page 15: ...e base body not the actuator of the P 603 with a lint free cloth that is dampened with a mild cleanser e g isopropanol or ethanol Customer Service For inquiries and orders contact your PI sales engine...

Page 16: ...2 Unidir Repeatability 10 1 Sigma 7 10 20 nm Mechanical properties Stiffness in motion direction 0 3 0 14 0 06 as P 603 xS1 N m Resonant frequency no load 900 410 300 as P 603 xS1 Hz Resonant frequenc...

Page 17: ...he resolution of the system is only limited by the noise of the amplifier and measuring technology because PI piezo actuators are free of friction Ask about customized versions Maximum Ratings P 603 P...

Page 18: ...ions for the P 603 Area of application For indoor use only Maximum altitude 2000 m Air pressure 1100 hPa to 0 1 hPa Relative humidity Highest relative humidity 80 for temperatures up to 31 C Decreasin...

Page 19: ...21 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws Dimensions Dimensions in mm Note that a comma is used in the drawings instead of a decimal point Model A C D Unit P 603 1S1 1S2 1...

Page 20: ...ax 49 721 4846 1019 Email info pi ws www pi ws Pin Assignment Sensor connector P 603 xS2 only Figure 4 Sensor connector LEMO FFA 0S 304 CLAC32 front view Pin Function 1 Reference 5 V 2 Sensor 3 Sensor...

Page 21: ...nsor Red Sensor Only if the model has a sensor Yellow Sensor Only if the model has a sensor White GND Only if the model has a sensor Old Equipment Disposal In accordance with EU law electrical and ele...

Reviews: