10 Technical Data
42
Version: 1.2.0
MP125E
N470 Linear Actuator
The following graph shows the duty cycle in % depending on the number of steps per second.
Figure 14: Duty cycle in % vs. steps/s
Vacuumcompatible models
Number of steps
per second*
Operating time
Duty cycle (max.) / idle time
2000
60 s (max.)
10 % / 9 min
2000
10 s
10 % / 90 s
1000
120 s (max.)
20 % / 8 min
1000
10 s
20 % / 40 s
≤
200
unlimited
unlimited
* To be set via the
Maximum Motor Output
operating parameter (0x9) for the E-872.401
respectively
PIShift Steps per Second
for the E-870.