5 Installation
N470 Linear Actuator
MP125E
Version: 1.2.0
23
Preparing a vacuumcompatible N470 for connecting to the electronics
1.
Attach the respective connectors for the vacuum feedthrough to the stranded wire
ends of the N-470's cables on the vacuum side and on the air side:
−
Make sure that the stranded wires are assigned to each other as shown in the
connection diagram.
−
Connect the cable shield according to the figure above. If the cable shield cannot be
connected to a pin, connect the respective cable shield to the housing.
2.
Check the lines for contacting and short-circuiting using a suitable measuring device.