NOTICE
Damage due to mechanical stress on the cable!
The cable will break from excessive or repeated bending. A broken cable will lead to failure
of the L-505.013212 or damage to the L-505.013212 or the electronics.
►
Install the L-505.013212 so that the cable has a bending radius of
≥
35 mm.
►
If necessary: Use cables that are approved for recurring mechanical loading (e.g., drag
chain cables).
Tools and Accessories
■
Adapter bracket, available as
■
Mounting hardware, included in the scope of delivery of the L-505
■
4 screws, ISO 4762, M3×6, A2
■
2 locating pins, ISO 2338, 2h8×8
■
Mounting hardware, included in the scope of delivery of the mounting bracket
■
4 screws, ISO 4762, M3×6, A2
■
2 locating pins, ISO 2338, 2h8×8
Building a Vertical Multi-Axis System
1. Attach the adapter bracket to the lower L-505.
a) Insert two locating pins into the motion platform of the lower L-505.
b) Align the adapter bracket to the lower L-505.
c) Insert the screws into the holes in the adapter bracket and tighten them.