User Manual
F712T0002, valid for F-712.MA1 and F-712.MA2
Mma, BRo, 12/6/2019
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany
Page 28 / 45
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email
Interconnecting the System
1.
Ensure that the power switch of the controller is in OFF position.
2.
Connect the mechanics to the controller. Observe the connection diagram that matches
your system (F-712.MA1 or F-712.MA2), see figures below.
3.
Prepare the mechanical setup for the optical components on sender and receiver side
(not shown in the figures below).
4.
Connect the signal to be measured to the controller:
a)
Connect the fiber from the receiver side of the system to the input connector of the
power meter device (not shown in the figures below).
b)
Connect the analog output signal of the power meter device to the controller via
the E-711.I1B analog input cable. Usually, the
In 1
socket of the E-711.IA4 analog
interface module in the controller is used.
5.
Connect the controller to a power source and to a PC according to the instructions in
the controller documentation (p. 5).
Figure 19: F-712.MA1 cabling scheme