background image

MPI-II user manual

(english)

 

Art.Nr. 9352

Art.Nr. 9352.05M
Art.Nr. 9352.10M
Art.Nr. 9352.15M

14.05.2019 

© PI 2019 

Summary of Contents for 9352

Page 1: ...MPI II user manual english Art Nr 9352 Art Nr 9352 05M Art Nr 9352 10M Art Nr 9352 15M 14 05 2019 PI 2019...

Page 2: ...ro RunTime RT Configuration 25 5 3 3 SIMATIC Step 7 Manager v5 2 SP1 26 5 3 4 Windows Control Center WinCC v6 0 26 5 3 4 1 MPI Configuration 28 5 3 4 2 TCP IP Configuration 29 5 3 4 3 Communication an...

Page 3: ...3 4 3 1 Setup 69 8 3 4 3 2 TS function 70 8 3 4 3 3 configure adapter 70 8 3 4 3 4 Import parameter 78 8 3 4 3 5 Export parameter 78 8 3 5 Tuning 79 9 PLC VCOM 80 9 1 Description 80 9 2 Installation...

Page 4: ...n automatic selection of the MPI Baudrate is possible The MPI II Cable is power supplied from the PLC and needs then no external supply Over an external connector it is possible to supply 24V to the C...

Page 5: ...lf If you want to connect the cable to the 25 pin connector of the PC you can use an adapter 9 pin to 25 pin sub miniature D connector to work with this port The PLC Programmingapplication PG95 PG 200...

Page 6: ...PLC please install following products for MPI USB S7 USB MPI II only USB MPI LAN and S7 LAN Product Driver TIA Portal TIC TIC ETH USB for MPI PPI or PROFIBUS configuration of driver with controll pane...

Page 7: ...I Kabel over USB as well as the devices of TeleService familiy will be connected to USB 1 1 compatible port of the PC This opens the Hardware Installation Wizard We don t need a connection to Windows...

Page 8: ...the folder USB Treiber x86 Either in the folder where the downloaded drivers were extracted or the directory on the product CD The message of windows logo test skip with Continue Anyway Handbook MPI...

Page 9: ...pying the data appears a little moment later the success message Upon a successful installation the PI_Usb Sys driver will be displayed without any warnings in the device manager Page 9 of 92 Handbook...

Page 10: ...ated please use the function Update in the driver properties If the driver has to be deleted please use the function Uninstall in the driver properties If you install older versions of PLCVCom Step7 d...

Page 11: ...fter the first plug of the device Win7 displays the message Nach dem ersten Anstecken am PC meldet Win7 zuerst Installing device driver software and after some time Device driver software was not inst...

Page 12: ...With a right mouse button click you will open the properties of the new device Handbook MPI II Page 12 of 92...

Page 13: ...Now select Update Driver Page 13 of 92 Handbook MPI II...

Page 14: ...lder USB Treiber x64 Either in the folder where the downloaded drivers were extracted or the directory on the product CD After pressing Next the message appears of windows UAC Please press install and...

Page 15: ...sful installation you can look again in the device manager Here may appear no exclamation mark If the driver has to be updated please use the function Update driver in the driver properties Page 15 of...

Page 16: ...x in Delete the driver software for this device If you install older versions of PLCVCom Step7 direct driver or S7IFC the actual usb driver will be possible overwritten by previous versions because it...

Page 17: ...ds Enhancement a value DOWN Navigate downwards Depreciation a value 4 2 Display First line 02PD00 Second line 02AG04 Display description from left to right First line 02 In this example there are two...

Page 18: ...If this sign appears in the bottom of the line your cable is communicating with the computer Second Line Exclamation mark specifies the connection type to the PLC Display Description Directly connect...

Page 19: ...amming device or to your computer If you want to respond to a PLC via the module you have to comply the requirements as descript in the chapter system requirements In addition please make sure that th...

Page 20: ...ess of the module 4 Choose the desired MPI cable and click OK to go on 5 If the connection is established the chosen cable is shown in the section state and on the left side you can see the status con...

Page 21: ...section Interfaces 4 Configure the baud rate in the section Bus access to 19 2k Below change the value for PC MPI to 187 5kBaud 5 Save your configuration by pressing OK 6 Now the software is ready to...

Page 22: ...enter WinCC v6 0 Windows Control Center flexible 2004 WinCC flexible v5 2 0 0 ProTool Pro v6 0 SP2 Microwin 3 2 1 Open the system configuration by using the start menu 2 Click on Set PG PC interface 3...

Page 23: ...to the PG PC interface configuration 5 In the dialog Select choose TCP IP and click on Install 6 After successful installation click Close 7 Back to the Set PG PC interface dialog you will now find t...

Page 24: ...ch for your device with Search Device Select the device in the result windows and click on the button Apply 10 Activate the Automatic mode when you will be shure that the connected PLC sends cyclic bu...

Page 25: ...etting 12 Mark the entry TIC ETH USB PROFIBUS and click on Properties 13 Open the properties dialog 14 Is the device type is not identical with your used device search for your device with Search Devi...

Page 26: ...parameter protocols When not please configure the bus by hand 16 Save your configuration with OK and close the Set PG PC interface dialog with OK 5 3 2 4 TCP IP RFC1006 setting 17 For this kind of co...

Page 27: ...ware which you want to use SIMATIC Step 7 Manager v5 2 SP1 Windows Control Center WinCC v6 0 Windows Control Center flexible 2004 WinCC flexible v5 2 0 0 ProTool Pro v6 0 SP2 Microwin 3 2 5 3 3 SIMATI...

Page 28: ...ou several project types Single User Project Multi User Project and Client Project The next steps are the describing for the Single User Project 4 OK leads you to a new dialog Type in the Project Name...

Page 29: ...hat the selected driver fits with the PLC otherwise the connection cannot be established 8 You should see now in the Explorer under the branch Tag Management the branch SIMATIC S7 PROTOCOL SUITE Expan...

Page 30: ...uration a new dialog will appear Now you are able to set the properties of the connection Set up the station address of the PLC in this example 2 Confirm with OK until you are back to the main window...

Page 31: ...perties 12 In this Channel unit properties you are able to see all available connections Choose the latest created connection and click again on Properties Now you can see all the variables which has...

Page 32: ...IC begins with a TCP IP 17 Confirm with OK 18 Now you are able to start the communication Stop it by clicking on 5 3 4 3 Communication and fault diagnosis To clean up errors faster the WinCC Software...

Page 33: ...Windows Control Center flexible 2004 WinCC flexible v5 2 0 0 Please make sure that the interface configuration is correct as described in PD PC Set interface 1 Start the WinCC flexible 2004 software...

Page 34: ...of the terminal HMI in this example 1 the Profile MPI for example the Highest Station Address HSA e g 126 the address of the PLC e g 2 6 Now you can start with your work If you have finished work you...

Page 35: ...the start menu 2 Choose from the menu File the sub menu New or click on the right symbol 3 The next dialog askes you which operator panel you are using Mark the used panel e g TP 170A 4 Next leads you...

Page 36: ...on File Transfer Settings Choose MPI PROFIBUS DP from the listbox and type in the station address of the operator panel e g 1 Confirm with OK and start with your work If you have finished working on t...

Page 37: ...the PLC Type e g CPU 224 as well as the CPU Version e g 01 22 to the dialog 3 Click on Communications to start the next dialog In the sector Address set up the Remote listbox with the station address...

Page 38: ...developed that more devices can communicate parallel with one PLC The following steps describe how to configure this mode in hardware and software 2 The module or cable has to switched in the PPIMult...

Page 39: ...s 8 In the menu PPI you are able to configure diverse settings like for e g HSA 9 In the menu Local Connection you select the com port Interface to to the port which is served from the tool PLCVCom 10...

Page 40: ...PLC was found the picture changes it like this 13 Prove the dialog with OK until you would be in the main window The communication to the PLC is now ready 5 3 9 S7 for Windows v5 02 Handbook MPI II Pa...

Page 41: ...Area Preferences from PC Area PLC Type S7 Area Protocol MPI Umsetzer Area Serial Port Choose the virtual COM port which has been created by PLC VCom e g COM 4 Area Baud Rate Choose the speed you want...

Page 42: ...t button for testing the new established communication configuration 8 Please wait a moment for the software to read the desired blocks from the PLC The blocks will be displayed in the listbox below t...

Page 43: ...atus This should now display SNDUSB in the first line and 38k4 N81 in the second line The MPI II MPI USB cable has been adjusted for the configuration of the operating terminal The configuration of th...

Page 44: ...apter Control elements 6 1 1 Graphical Description With enter you will get in the menu of the cable This menu has the following structure MENU Message MENU Config MENU Bus MENU Info Standard display S...

Page 45: ...SB MPI communication with PLCVCom Step7 driver over USB interface PPI 9K6 PPI communication with 9600 baud over RS232 interface PPI 19K2 PPI communication with 19200 baud over RS232 interface PPIUSB96...

Page 46: ...protocol version Choose Auto if you want that the cable takes the configuration from the PG If you experience any trouble on the bus with the protocol version V 5 1 set the configuration to V5 0 Old T...

Page 47: ...al values of 00 to 7E are possible HSA HSA stands for Highest Station Address Configure the highest station number to the cable which is connected to the MPI bus Possible values 15 31 63 126 The setti...

Page 48: ...Letter Description D The MPI cable is directly connected to the PLC A This station is active in the bus P This station is passive in the bus for e g some OP s FM blocks also MPI Bus Slaves 6 1 4 Info...

Page 49: ...d by USB LAN Search devices on all network cards The button Search starts a parallel search on all selected interfaces After selecting a updateable device the button Update gets available Below the bu...

Page 50: ...ap sets the firmware configuration to factory default The button Factory defaults sets the configuration to factory default The button Parameterize activates a dialog regarding to the device Overview...

Page 51: ...to the device you maybe have to click on the button Bus configuration see parameterize table Here you can parameterize the following Use bus config for PC Tooks the bus configuration from the PC Baud...

Page 52: ...n number for 2 different stations Protocol type Protocol type of the connection Boot settings Boot setting of the connection 7 4 Network settings Here you can set the network configuration of the sele...

Page 53: ...device after that on Parameterize Regarding to the device you maybe have to click on the TELEService button After clicking on TELEService a message will show up Depending on the version of your TELES...

Page 54: ...d Never use the same station number for 2 different stations Network related Network type The network type MPI or PROFIBUS Transmission rate The transmission speed on the MPI bus Current transfer rate...

Page 55: ...g up Switch to command mode AT start command H Hang up connection Location The phone system uses There are two possible call techniques MFV tone the telephone number is transfered by several frequenci...

Page 56: ...ter In this dialog the transfer rate between modem and TS Adapter is selected Connection Preferences Transfer rate The transfer rate could choosen between the follwing values 2400 4800 9600 19 2k 38 4...

Page 57: ...so you must call again not like the original TS adapter After changing the password for a user administrator you must re type it again correctly You can enter a callback number which is used for a ca...

Page 58: ...N Modem Type Choose the type of the ISDN network AT T 5ESS Nothern Telecom DMS 100 EuroISDN NET3 Standard INS64 US NI 1 VN4 Protocol Choose the transfer protocol type Modem like V 120 X 75 Standard ML...

Page 59: ...n is displayed Display Description Automatic The provider is automatically searched and selected from the GSM modem Manual The Provider is selected manually from the GSM Modem no network registered No...

Page 60: ...high costs The radio quality is displayed together with the bit error rate Value Description 99 No network no receive 00 Very very bad receive quality 01 Very bad receive quality 02 to 09 Bad receive...

Page 61: ...ervice GSM Receive of DTMF only with TELEService GSM Bus address TS local station address should not be used twice in the MPI Profibus Bus address CPU from this station address the flag word and data...

Page 62: ...is a 5V Type Possible MPI Bus error messages MPI Profibus Configuration erroneous Timeout at MPI Profibus detach from device The local station address is used twice in the MPI Profibus A20 M20 TC35 M...

Page 63: ...ngth UUU ErrCode 15 The upper 4 Bit of the Function code are wrong unknown CPU XXX SSAP YYh FC ZZh length UUU ErrCode 16 Unknown function code has been transmitted to the cable CPU XXX SSAP YYh FC ZZh...

Page 64: ...access Password Userpassword for the Internet access Mail Server Name of the SMTP Email Servers which is used to send the E Mail Mail from Source E Mail Address should be from the same Free mailer ins...

Page 65: ...lines on the serial port are not used In that case the TELEService function is not working With this property the control lines are no longer used and therefore the A20 M20 can communicate over TELEs...

Page 66: ...utton sets the configuration of the selected device to factory defaults 7 8 PPI Boot off In PPI boot mode S7IFC cannot communicate with the cable To disable the PPI boot mode click on the button PPI B...

Page 67: ...MPI LAN cable Art ID 9352 LAN S7 LAN module Art ID 9352 LANCon MPI USB cable Art ID 9352 USB S7 USB module Art ID 9352 S7 USB MPI II cable USB operation Art ID 9352 9352 1 MPI PPI cable Art ID 9350 Te...

Page 68: ...startup items Then click Continue 4 Wait for the installation of the files 5 End the installation after a successful copy of data with Finish 8 3 Overview 8 3 1 Language After starting the application...

Page 69: ...aktive at starting the MPI Kabel Manager are shown Search update the COM port listed in set interface and put the Kabelmanager to the respective COM port For access query choose Direct if your produc...

Page 70: ...n check your cable which is connected to the COM Port reviewed The symbol next to version check shows the running update While update do not plug out the cable from the PLC or turn off the power suppl...

Page 71: ...IP code and country Telephone number you can reach the TS adapter 8 3 4 2 Connect At the moment not implemented In this dialog the connection to another modem with a MPI cable connected is started Cho...

Page 72: ...tion The MPI cable acts like an TS Adapter There will an answer to TS spezific protocols the adapter could now configured An attached Modem will be initiliazed and the baud rate to the modem is fixed...

Page 73: ...as TS or PC adapter Right of this button the actual state of the MPI cable is displayed 8 3 4 3 3 configure adapter In the following dialog you could after activating the MPI cable as TS adapter confi...

Page 74: ...station adress in the bus the less you use the more performanceon the MPI bus must be corresponding with the configuration in the PLC s Modem In this dialog you could configure the modem related setu...

Page 75: ...ure the number of retries for a connection before the call is stopped When using a retry you could choose the seconds which the application should wait between calls Serial parameter In this dialog th...

Page 76: ...g retries the connection is hanged up so you must call again Not so with an original TS adapter After changing the password for one user administrator you must re type it again correctly before it is...

Page 77: ...em ISDN modem Type Choose the type of the ISDN network switch AT T 5ESS Nothern Telecom DMS 100 EuroISDN NET3 Standard INS64 US NI 1 VN4 Protocol Choose the transfer protocol type Modem like V 120 X 7...

Page 78: ...d and selected from the GSM modem Manual The Provider is selected manually from the GSM Modem no network registered No connection to the GSM network the receive quality is too bad set format The forma...

Page 79: ...ted Phone line or telephone busy Phone number is blacklisted in modem Phone number delayed Access denied for 1 minute Fax call detected Data call detected unknown error The selected direct access numb...

Page 80: ...XX SSAP YYh FC ZZh length UUU ErrCode 13 The sender XXX of the received data protocol is unknown To send data the participant must get the Token SSAP YYh FC ZZh length UUU ErrCode 14 The 7th Bit of th...

Page 81: ...ly with with TELESERVICE GSM TS local station address should not be used twice in the MPI Profibus PLC from this station address the Flagword and Data block is accessed for communication MW communicat...

Page 82: ...they will be transferred to the MPI Cable by pressing the button Transfer The configuration is saved permanently in the Flash ROM Time to send At ProTool RT the communication could break down because...

Page 83: ...s so no communication is starting If this occurs you could choose that the cable is working as MPI Adapter only Language You could select the language which is used from the cable German or English 9...

Page 84: ...sing Windows NT 2000 XP This part of the description is for the operating systems Windows NT 2000 XP If you are using Windows 98SE or ME please read the description Final configuration of the PLC VCOM...

Page 85: ...icking in the application folder of your start menu on SelectCOM 9 The installation ends with a click on OK 9 2 3 USB driver installation using Windows 98SE ME After you have finished the installation...

Page 86: ...d show a dialog which is equal to the picture below Click on Next to start the installation 15 After the installation finished successful click on Ready to end this installation 16 The installation is...

Page 87: ...LAN modules MPI S7 LAN Configuration of your MPI LAN or S7LAN 2 Info information about the PLC VCOM and your computer 3 Status Display the connection parameters of the cable connected Top left shows...

Page 88: ...ntry allows you to enter the parameters manually no network for products which are not in any network Installing in the device Manager Installs the PLC VCOM COM port in Device Manager required only fo...

Page 89: ...2 W hlen Sie das gew nschte Kabel Modul aus so dass es blau markiert ist Hierbei werden alle Parameter automatisch in den Konfigurations Assistenten bernommen 9 4 1 2 Manual Die manuelle Eingabe betri...

Page 90: ...Supply voltage 24V DC 20 Power consumption 2 5 watt Display double lined LCD display Handling Configuration Kabelmanager Software keypad on the back Interfaces to the PLC PPI MPI Profibus interface 9...

Page 91: ...at the SUB D connector For an extension of the cable please supply the cable with external power and only prolong the signals Ltg_A and Ltg_B 1 1 Connect the shield on the SUB D connector possibly inc...

Page 92: ...this side this side also supports the 5V DC power supply max cable length are 5 meters A longer cable would decrease the quality of the signal on the bus and may cause several errors in the transmissi...