background image

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12933-01 / 4521

 

Take  the  temperatu

re  and  atmospheric  pressure  into 

consideration. 

hPa: 

mmHg: 

1026,5 

770 

1013,3 

760 

999,9 

750 

986,6 

740 

973,3 

730 

16°C 

10.07 

9.94 

9.81 

9.68 

9.55 

17°C 

9.86 

9.74 

9.61 

9.48 

9.35 

18°C 

9.67 

9.54 

9.41 

9.29 

9.16 

19°C 

9.47 

9.35 

9.23 

9.11 

8.98 

20°C 

9.29 

9.17 

9.05 

8.93 

8.81 

21°C 

9.11 

9.00 

8.88 

8.76 

8.64 

22°C 

8.94 

8.83 

8.71 

8.59 

8.48 

23°C 

8.78 

8.66 

8.55 

8.44 

8.32 

24°C 

8.62 

8.51 

8.40 

8.28 

8.17 

25°C 

8.47 

8.36 

8.25 

8.14 

8.03 

26°C 

8.32 

8.21 

8.10 

7.99 

7.89 

27°C 

8.17 

8.07 

7.96 

7.86 

7.75 

28°C 

8.04 

7.93 

7.83 

7.72 

7.62 

29°C 

7.90 

7.80 

7.69 

7.59 

7.49 

30°C 

7.77 

7.67 

7.57 

7.47 

7.36 

31°C 

7.64 

7.54 

7.44 

7.34 

7.24 

32°C 

7.51 

7.42 

7.32 

7.22 

7.12 

33°C 

7.39 

7.29 

7.20 

7.10 

7.01 

34°C 

7.27 

7.17 

7.08 

6.98 

6.89 

35°C 

7.15 

7.05 

6.96 

6.87 

6.78 

 

hPa: 

mmHg: 

959,9 

720 

946,6 

710 

933,3 

700 

919,9 

690 

906,6 

680 

16°C 

9.42 

9.29 

9.15 

9.02 

8.89 

17°C 

9.22 

9.10 

8.97 

8.84 

8.71 

18°C 

9.04 

8.91 

8.79 

8.66 

8.54 

19°C 

8.86 

8.74 

8.61 

8.49 

8.37 

20°C 

8.69 

8.57 

8.45 

8.33 

8.20 

21°C 

8.52 

8.40 

8.28 

8.17 

8.05 

22°C 

8.36 

8.25 

8.13 

8.01 

7.90 

23°C 

8.21 

8.09 

7.98 

7.87 

7.75 

24°C 

8.06 

7.95 

7.84 

7.72 

7.61 

25°C 

7.92 

7.81 

7.70 

7.59 

7.48 

26°C 

7.78 

7.67 

7.56 

7.45 

7.35 

27°C 

7.64 

7.54 

7.43 

7.33 

7.22 

28°C 

7.51 

7.41 

7.30 

7.20 

7.10 

29°C 

7.39 

7.28 

7.18 

7.08 

6.98 

30°C 

7.26 

7.16 

7.06 

6.96 

6.86 

31°C 

7.14 

7.04 

6.94 

6.85 

6.75 

32°C 

7.03 

6.93 

6.83 

6.73 

6.63 

33°C 

6.91 

6.81 

6.72 

6.62 

6.53 

34°C 

6.80 

6.70 

6.61 

6.51 

6.42 

35°C 

6.68 

6.59 

6.50 

6.40 

6.31 

 
 

5.5 Care 

 

Membrane 
Ensure not to damage the membrane and follow the storage 
instructions in order to increase the service life of the elec-
trode. Creases or holes in the membrane are a sign that it 
does not work properly any more. 
If the membrane is soiled or if it shows signs of damage (this 
might be indicated by incorrect measurement values), use a 
spare cap with a membrane. 
 
 
 

Cathode and anode 
They must be polished with polishing cloths from time to time. 
To do so, remove the cap so that the anode and cathode can 
be accessed. Polish them with slight pressure and a clean 
cleaning cloth in order to remove any deposits from the sur-
face. Rinse them with distilled water and then with alcohol, 
shake the liquid off, and screw the cap back on loosely. 

6  TECHNICAL DATA  

Operating temperature range: 5 - 40°C 
Rel. humidity < 80% 
 
Oxygen in air: 
Measuring range 
Resolution 
Accuracy 
Oxygen in liquid: 
Measuring range 
Resolution 
Accuracy (10~35°C) 
 

 

0…100 %  

0.1 % 

±2% 

 

0…20 mg/l 

0.01 mg/l 

±0.5mg/L 

Max. date rate 
Battery capacity 
Max. wireless range (open field) 

10 Hz 

250 mAh 

30 m 

Dimensions (length x width x height) 

85 x 40 x 23 mm 

Weight 

40 g 

7  SCOPE OF DELIVERY 

The extent of delivery is as follows  

 

Cobra SMARTsense Oxygen 

12933-01 

 

USB connecting cable type C 

07935-00 

 

Dissolved and Air Oxygen Electrode 

 

 

 

Operating instructions 

8  ACCESSORIES 

The following accessories are available: 

 

Cobra SMARTlink 

12999-99 

 

USB-charger 

07934-99 

 

USB connecting cable type C 

07935-00 

 

USB-Bluetooth-Adapter 

07936-00 

 

Calibration solution Zero Oxygen, 500 ml 

47072-50 

 

Software measureLAB 

14580-61 

 

Free measureApp available from supplier portals 

iOS 

 

Android 

 

Windows 

 

 
 
 
 
 
 
 
 

Reviews: