Main supply POWM01:
Fig. 2: POWM01
Feed-in to the power supply:
•
24 to 70 V
DC
supply voltage (for motors and generates internally the logic voltages) –
20 A max.
•
Optional electrically isolated 24 V
DC
for inputs/outputs, limit and reference switches
Configuration:
•
USB interface for programming and diagnostics
•
Device address switch
•
Remote/Local switch
•
Reset button
•
Connection of an external phytron touch panel (projected 2012)
The external supply must be designed for the required current (e.g. by the
SPH 240-2410-24 power supply unit).