Manual PIDM01
MA 1311-A001 EN
12
4 digital (PID control)
outputs
O1 to O4
Output level:
24 V
DC
for internal power supply
with external supply: external supply
– 1 V
Output current max.: 1 A per output
Total output current:
2 A for internal power supply
4 A for external power supply
Short circuit proof
Thermal overload protection
Switching frequency max.: 1 kHz
24 V
DC
supply
24 V
DC
internal and 2 A max. at the central supply via the
delivering modules POWM.
30 V
DC
external and 4 A max. when delivered directly to the
PIDM module The external power supply must always be
higher than the internal power supply.
Rear bus connection
Proprietary Phytron bus
Communication and Programming
Programming
Via
Phytron’s programming environment
phyLOGIC
TM
ToolBox
Communication
Master slave communication from the MCM to the PIDM01