dry sponge and bring them together. This will cause each of them to try and neutralize the 
other. The basin will lose water and the dry sponge will gain water. This same neutralizing 
principle happens with plants. Take a plant and put it into a dry (low humidity) 
environment and the plant will transpire more than usual. As the Relative Humidity in the 
air increases, provided the Air & Leaf Temperatures remain constant, the VPD decreases 
and the plant transpires less. If the Leaf Temperature increases and the Relative Humidity 
and Air Temperature remain constant, the VPD increases and the plant transpires more. If 
the Air Temperature decreases and the Relative Humidity and Leaf Temperature remain 
constant, the VPD increases and the plant transpires more. As you can see, all the 
environmental factors (Air Temperature, Leaf Temperature, and Relative Humidity) play a 
part in the water lost by plants through transpiration. If the Air Temperature and the Leaf 
Temperature are the same and the Relative Humidity of the Air is 100%, there would be no 
VPD. 
 

HOW TO DETERMINE CORRECT WATERING TARGETS 

 

FIXED TARGET: 

To establish Fixed Targets for Mist or Irrigation, use the Manual Mode, the Set System 
Mode and the Set Station Mode exclusively. The Set Station Mode is where the target is 
entered. The Manual Mode is where the station is activated to zero out the VPD 
accumulation. The Set System Mode is where the accumulated VPD information is 
displayed as it approaches the target that was entered in the Set Station Mode. When a 
station (zone) needs to be watered, read the accumulated VPD in Set System for that 
station and that will be the correct watering target. After doing this a couple of times, a 
perfect fixed target for the station will be established. 
 
If the crop is presently being watered using time intervals, there is a shortcut to establish a 
target. During an interval when the timing method being used is delivering water to the 
plants adequately, do the following: 
 

1. Set up a station with a High Fixed Target (1000 for Mist and 50,000 for 
Irrigation). The objective will be to NOT hit the target while in the process of 
calculating what the target should actually be. 
2. When the timer or other device being used waters the plants, go into the Manual 
Mode and Trigger the Station with the high fixed target. 
To do this: 

a) Use the 

RUN/SET

 switch to go into the Manual Mode. 

b) Use the 

VALUE

 switch to answer YES for the Mist Station or enter the 

number 
of times for the Irrigation Station. 
c) Push the 

PRIOR/NEXT

 switch toward the NEXT position to activate the 

station. Leave the 

ON/OFF/AUTO

 Switch for this station in the OFF 

position. The station will zero-out the current VPD Accumulation and start 
accumulating toward the High Target. 

3. The very next interval that the timer waters the plants, check the current VPD 
Accumulation for the station. This is the target! Divide this target by the number of 

Summary of Contents for WATER PRO

Page 1: ...13688 Rider Trl N Earth City MO 63045 PHONE 314 770 0717 FAX 314 506 4587 www phytotronics com Revision 1 2 10 15 2021 Water Pro VPD Misting and Irrigation Control...

Page 2: ...er ELECTRICAL CIRCUIT The electrical circuit that feeds the machine tool transformer must have no other loads connected to it This will prevent damaging surges from other related electrical devices Fo...

Page 3: ...from your solenoid valves 24VAC type to the WATER PRO EXPANSION module plugs 3 Make sure all plugs are secured into the WATER PRO EXPANSION module then turn the screw locking the panel in its enclosur...

Page 4: ...vating the next Output Station FEATURES OF THE EQUIPMENT INPUTS and OUTPUTS The Sensor Inputs to the WATER PRO are as follows 1 Air Temperature 1 from VPD Sensor 1 2 Leaf Temperature 1 from VPD Sensor...

Page 5: ...r Air Temperature 1 Leaf Temperature 1 Relative Humidity 1 Air Temperature 2 If optional sensor installed Leaf Temperature 2 If optional sensor installed Relative Humidity 2 If optional sensor install...

Page 6: ...of time left on an active watering cycle Note Answer all questions with only the number of stations crop aging groups and disable groups that are currently being set up This will prevent the unit fro...

Page 7: ...nrise When attaching the Disable Group to an irrigation station the irrigation station will disable for the amount of time called for in the Disable Group prior to Sunset No matter what type of statio...

Page 8: ...wo mists This gives the VPD per minute For each daily target calculate how much time between each misting for that specific day if the environmental conditions were identical to the first target Multi...

Page 9: ...lant must have water After watering the plant the process starts all over again Just what is VPD and how does it relate to plants To understand VPD we must understand the following 1 How water moves t...

Page 10: ...he VPD accumulation The Set System Mode is where the accumulated VPD information is displayed as it approaches the target that was entered in the Set Station Mode When a station zone needs to be water...

Page 11: ...be 2 When the timer or other device waters the plants go into the Manual Mode and Trigger the Station with the high fixed target To do this a Use the RUN SET switch to go into the Manual Mode b Use th...

Page 12: ...get If attempting to determine a new target enter a high target 1000 for a misting station and 50 000 for an irrigation station Use the VALUE and the PRIOR NEXT switches to enter this target Refer to...

Page 13: ...program or to Stop Watering Use the VALUE switch to enter this choice 36 Push the PRIOR NEXT switch to NEXT to go to the next question 37 Choose whether or not to use a DISABLE program Use the VALUE...

Page 14: ...go to the next question 11 Choose the final day target If attempting to determine this target refer to the section How To Determine Correct Watering Targets 12 Push the PRIOR NEXT switch to NEXT to go...

Page 15: ...sunrise 8 Push the PRIOR NEXT switch to NEXT to go to the next question WARNING If this is the FIRST TIME this crop age program has been set up choose Yes Reset First The WATER PRO resets the targets...

Page 16: ...lations Only in the Manual Mode can the VPD Accumulation for a station be zeroed out NOTE USE OF THE ON OFF AUTO SWITCHES DO NOT ZERO OUT VPD ACCUMULATIONS Example 2 TRIG STATION 1 If the zone connect...

Page 17: ...17...

Page 18: ...only and sole liability of Phytotronics Inc under this warranty is limited to repairing replacing or the issuance of credit for any products returned to Phytotronics Inc during the warranty period of...

Reviews: