phyBOARD-Regor AM335x [PB-01802-xxx]
12
PHYTEC Messtechnik GmbH 2018 L-823e_2
2.2.1.3
Status LEDs D66 and D67
Figure 7:
LEDs D66 and D67 with Switch S2
The status-LEDs D66 and D67 are located next to the reset button and are visible at the
front of the housing.
LED D66 indicates the RUN/STOP status of the phyBOARD-Regor. This LED is green and can
be used to show if the module is currently running.
The ERROR-LED D67 is red and can be used to indicate if there is an error with the module.
and
show the location of the two LEDs.
2.2.1.4
Backup Supply
The phyBOARD-Regor is equipped with a Gold Capacitor (C339 placed next to connector X6)
which is intended to back up the external RTC (
) on the SBC. This voltage
source is also connected to the backup voltage pin VBAT (A2) of the phyCORE-AM335x and
supplies the module's RTC and some critical registers of the Power Management IC when
the primary system power, X_VIN, is removed. The backup supply lasts approximately 7
days.