background image

 

 

 

A product of a PHYTEC Technology Holding company 

phyBOARD

®

-Regor AM335x 

Application Guide 

 

Document No.: 

L-823e_2 

 

 

 

SBC Prod. No.: 

PB-01802-xxx 

 

CB PCB No.: 

1447.3 

 

SOM PCB No.: 

1358.4 

 

Edition: 

June 2018 

Summary of Contents for phyBOARD Regor AM335x

Page 1: ...A product of a PHYTEC Technology Holding company phyBOARD Regor AM335x Application Guide Document No L 823e_2 SBC Prod No PB 01802 xxx CB PCB No 1447 3 SOM PCB No 1358 4 Edition June 2018...

Page 2: ...for doing so Copyright 2018 PHYTEC Messtechnik GmbH D 55129 Mainz Rights including those of translation reprint broadcast photomechanical or similar reproduction and storage or processing in computer...

Page 3: ...Power Connector X1 10 2 2 1 2 Power LEDs D62 D63 and D68 11 2 2 1 3 Status LEDs D66 and D67 12 2 2 1 4 Backup Supply 12 2 2 2 UART Connectivity X3 X5 X6 X7 13 2 2 2 1 RS 232 Connectivity X5 14 2 2 2...

Page 4: ...r AM335x Switch Locations 8 Figure 6 Power Supply Connector X1 10 Figure 7 LEDs D66 and D67 with Switch S2 12 Figure 9 RS 485 Interface Connector X3 15 Figure 10 Components supporting the CAN Interfac...

Page 5: ...ntact MINI COMBICON Base Strip X1 11 Table 7 Connectors and Signal Levels of the UART Interfaces 13 Table 8 Pin Assignment of the RS 232 Interface at Connector X5 14 Table 9 Pin Assignment of the RS 4...

Page 6: ...l name e g RD are designated as active low signals That is their active state is when they are driven low or are driving low A 0 indicates a logic zero or low level signal while a 1 represents a logic...

Page 7: ...input and output GPO General purpose output IRAM Internal RAM the internal static RAM on the Texas Instruments AM335x microcontroller J Solder jumper these types of jumpers require solder equipment t...

Page 8: ...entary information about the topic The BSP delivered with the phyBOARD Regor AM335x usually includes drivers and or software for controlling all components such as interfaces memory etc Therefore prog...

Page 9: ...tomer requirements with little development effort and thus greatly reduce the time to market The core of the SBCplus concept is the SBC design library a kind of construction set that consists of a gre...

Page 10: ...on hardware peripherals and firmware without expending resources to re invent microcontroller circuitry Furthermore much of the value of the phyBOARD SBC lies in its layout and test Software Support P...

Page 11: ...n notes FAQs etc http www phytec de produkt single board computer phyboard regor Other Products and Development Support Aside of the new phyBOARD family PHYTEC supports a variety of 8 16 and 32 bit co...

Page 12: ...ained personnel such as electricians technicians and engineers handle and or operate these products Moreover PHYTEC products should not be operated without protection circuitry if connections to the p...

Page 13: ...ges by evaluating longevity of parts during design in phase Ensure availability of equivalent second source parts Stay in close contact with part vendors to be aware of roadmap strategies Change manag...

Page 14: ...phyBOARD Regor AM335x PB 01802 xxx xii PHYTEC Messtechnik GmbH 2018 L 823e_2...

Page 15: ...rdance with PHYTEC s new SBCplus concept Preface PHYTEC s phyCORE AM335x SOM Phoenix Contact ME Max 3U1 standard dimensions Boot from SD card or NAND Flash Max 1 GHz core clock frequency Single supply...

Page 16: ...phyBOARD Regor AM335x PB 01802 xxx 2 PHYTEC Messtechnik GmbH 2018 L 823e_2 1 1 2 Block Diagram Figure 1 Block Diagram of the phyBOARD Regor AM335x...

Page 17: ...Introduction PHYTEC Messtechnik GmbH 2018 L 823e_2 3 1 1 3 View of the phyBOARD Regor AM335x Figure 2 View of the phyBOARD Regor AM335x with phyCORE AM335x Figure 3 phyBOARD Regor AM335x connectors...

Page 18: ...of each connector for easy identification Reference Designator Description See Section X1 Power supply 12 V 24 V 1 5 positions Phoenix Contact MINI COMBICON connector 3 5 mm pitch 2 2 1 1 X2 4 x digit...

Page 19: ...e or current Maximum signal input values are indicated in the corresponding controller User s Manual Data Sheets As damage from improper connections can vary according to use and application it is the...

Page 20: ...s in the housing Figure 4 shows the location of the LEDs Their functions are listed in Table 3 LED Color Description See Section D7 green Indicates presence of VBUS for the USB OTG interface at expans...

Page 21: ...Description See Section D68 green 3 3 V voltage on the output of the LDO has to be approved and enabled by supply voltage supervisor IC to supply the phyBOARD Regor 2 2 1 2 D66 green RUN STOP status...

Page 22: ...tions The phyBOARD Regor is populated with two switches one to reset the phyBOARD Regor and another to configure the boot sequence Figure 5 shows the location of the switches Their functions are liste...

Page 23: ...t also render the warranty invalid Because of this only the removable jumper is described in this section Contact the PHYTEC sales team if you need jumper configurations different from the default con...

Page 24: ...ith a 5 pole Phoenix Contact MINI COMBICON base strip 3 5 mm connector X1 suitable for a single 24 V 10 supply voltage The required current load capacity depends on the specific configuration of the p...

Page 25: ...e Strip X1 2 2 1 2 Power LEDs D62 D63 and D68 The LEDs D62 D63 and D68 indicate the presence of the 3 3 V D63 D68 and 5 V D62 supply voltage generated from the input voltage The presence of the 3 3 V...

Page 26: ...he ERROR LED D67 is red and can be used to indicate if there is an error with the module Figure 4 and Figure 7 show the location of the two LEDs 2 2 1 4 Backup Supply The phyBOARD Regor is equipped wi...

Page 27: ...ce refer to the appropriate chapter listed in the table UART Connector Signal level See Section UART0 standard console X5 1 5 positions Phoenix Contact MINI COMBICON connector 3 5 mm pitch RS 232 2 2...

Page 28: ...tive of the phyBOARD Regor The UART0 interface serves as the standard console output of the phyCORE AM335x module on the phyBOARD Regor The initial setting of the UART0 interface is specified to a bau...

Page 29: ...pitch Connector X3 is located on the right side of the board Figure 2 Figure 9 shows a detailed view of the X3 connector Table 9 shows the pin assignment of X3 In case jumpers J5 and J6 section 2 1 4...

Page 30: ...he Phoenix Contact MINI COMBICON connector X3 5 positions 3 5 mm pitch as shown in Figure 10 In case jumpers J5 and J6 section 2 1 4 are set to the respective positions the CAN interface signals are a...

Page 31: ...ivers support HP Auto MDIX eliminating the need for a direct connect LAN or a cross over path cable They detect the TX and RX pins of the connected device and automatically configure the PHY TX and RX...

Page 32: ...y configuring the OTG interface at X4 as slave USB1_ID is connected to GND and configures the OTG interface at expansion connector X6 as host Typically configuring a connecting device as host or slave...

Page 33: ...tion to peripheral devices like SD and MMC cards Power to the SD interface is supplied by inserting the appropriate card into the MMC SD connector which features card detection a lock mechanism and a...

Page 34: ...alvanic isolation Thus it is possible to write and read the status of every single GPIO of the phyBOARD Regor simultaneously Please consider that the GPIOs do not have a separate current driver on boa...

Page 35: ...Output connects to GPIO0_27 IN and GPIO1_15 OUT of the AM335x 2 DIGIO2 Digital Input Output connects to GPIO0_26 IN and GPIO1_14 OUT of the AM335x 3 DIGIO3 Digital Input Output connects to GPIO0_23 IN...

Page 36: ...the pin assignment shown in Table 13 Pin Signal Description 1 VIN Alternative Power supply for the phyBOARD Regor 24 V DC 10 2 GND Ground 3 VCC3V3 Power supply for external 3 3 V logic max 500 mA 41...

Page 37: ...ANDI2C MMC0 UART0 Boot mode 2 S4 ON SYSBOOT 4 0 10111b MMC0 SPI0 UART0 USB Table 14 Boot Switch Configuration for S4 2 2 10 System Reset Button S2 Figure 17 System Reset Button S2 The phyBOARD Regor i...

Page 38: ...on the phyCORE AM335x module It is used for real time or time driven applications Please note that if the RTC s interrupt is needed pin 37 X_INTR1_GPIO0_20 and pin 40 X_INT_RTCn at expansion connector...

Page 39: ...version of the carrier board The pinout of the expansion connector is shown in Table 15 Pin Signal Name Type SL Description 1 VCC3V3 OUT 3 3 V 3 3 V power supply 2 VCC5V OUT 5 0 V 5 V power supply 3 V...

Page 40: ...32 X_MMC2_DAT3 I O 3 3 V MMC data 33 33 X_UART2_TX_GPIO3_10 I O 3 3 V UART 2 transmit data GPIO3_104 34 GND Ground 35 X_UART3_RX_GPIO2_18 I O 3 3 V UART 3 receive data GPIO2_184 36 X_UART3_TX_GPIO2_19...

Page 41: ...Ground 60 VCC5V_IN IN 5 0 V 5 V input supply voltage Table 15 Pin Assignment of PHYTEC Expansion Connector X6 continued If the SPI NOR Flash on the phyCORE AM335x is populated the SPI signals on the e...

Page 42: ...pxc oc itemdetail pid 2201546 library usen pcck P 01 04 02 01 tab 1 Additional specifications Dimensions 100 mm x 100 mm Weight 129 g Storage temperature 40 C to 85 C Operating temperature refer to s...

Page 43: ...mance microcontrollers and other active parts like the ones described within this manual are usually rated by qualifications based on tolerable junction or case temperatures Therefore making a general...

Page 44: ...ng airflow if the system is mounted into a housing Heat resistance of the heat dissipation paths within the system along with the considered usage of a heat spreader or a heat sink to optimize heat di...

Page 45: ...Date Version Changes in this manual 30 08 2016 Manual L 823e_1 First edition Describes the phyBOARD Regor AM335x SOM PCB 1358 3 with phyBOARD Regor Carrier Board PCB 1447 1 27 06 2018 Manual L 823e_2...

Page 46: ...Humidity 28 J JP3 16 Jumpers 9 L LAN 17 LEDs 6 D62 11 12 D63 11 12 D68 11 D7 18 D8 18 LINK LED 17 M MAC Address 17 O Operating Temperature 28 Operating Voltage 28 P Peripherals 4 Pin Header 4 Power Co...

Page 47: ...phyBOARD Regor AM335x Document number L 823e_2 June 2018 How would you improve this manual Did you find any mistakes in this manual page Submitted by Customer number Name Company Address Return to PHY...

Page 48: ...phyBOARD Regor AM335x PB 01802 xxx Published by PHYTEC Messtechnik GmbH 2018 Ordering No L 823e_2 Printed in Germany...

Reviews: