Blood Pressure Monitor
Model: 106-930
P/N 921-106930E
Rev 1 0111
essen
Instruction Manual
Physio logic essentia Manual (ENG)
106-930
921-106930E
21.5 cm x 14.5 cm
21.5 x 14.5 cm (folded: 10.75 x 14.5 cm)
Instruction Booklet
Travis Fraser
TM
X
Page 1: ...r Model 106 930 P N 921 106930E Rev 1 0111 essen essen Instruction Manual Physio logic essentia Manual ENG 106 930 921 106930E 21 5 cm x 14 5 cm 21 5 x 14 5 cm folded 10 75 x 14 5 c Instruction Bookle...
Page 2: ...s important that you take home readings regularly and that you follow the procedures and precautions mentioned in the instruction manual Consistently recording charting your readings along with regula...
Page 3: ...y read this manual before using the product This Blood Pressure Monitor does not replace examination by a physician As your doctor is the one person best qualified to interpret your results we recomme...
Page 4: ...tant fluctuation throughout the day Blood pressure recording can be affected by the position of the user his or her physiological condition and other factors For greatest accuracy wait one hour after...
Page 5: ...FLATING CUFF IS DEFLATING DIASTOLIC BLOOD PRESSURE PULSE RATE MEMORY NUMBER INDICATOR LCD SCREEN SET BUTTON BUTTON BUTTON AIR JACK POWER BUTTON Your Monitor BATTERY COVER AC ADAPTOR SOCKET ARM CUFF AI...
Page 6: ...display appears dim The display does not light up CAUTION Selecting memory zone and setting date time unit of measurement It is important to set the clock before using your blood pressure monitor so...
Page 7: ...SET SET SET 10 10 6 6 38 38 18 18 AM AM M M D D 1 1 1 MEASUREMENT 1 Firmly insert air plug into opening located on left side of the monitor Prepare the cuff 2 Wrap the cuff around your upper left arm...
Page 8: ...tone indicates the device is ready for testing 2 Initial pressure is fi st pumped to 190mmHg The unit will automatically adjust to one of four pressure levels based on the current user s blood pressu...
Page 9: ...g mode 4 When testing is complete the monitor will sound three short beeps The screen will display your systolic and diastolic blood pressure The reading will be automatically stored in the selected m...
Page 10: ...off See Select Memory Zone on page 9 Readings can not be recovered once deleted 11 7 7 0 2 7 6 1 mmHg 1 1 10 10 6 6 38 38 18 18 AM AM M M D D No SET To delete all records from memory Y clear the memo...
Page 11: ...when taking a measurement How to clean and care for your blood pressure monitor Store in a dry place and avoid exposing to direct sunshine Use a damp cloth to clean your blood pressure unit Avoid int...
Page 12: ...irmly reposition cuff approximately 1 2 above the elbow joint Sit in a relaxed position with arm placed near heart Avoid speaking or moving body parts while testing Make sure the monitor unit is place...
Page 13: ...value 30 180 times minute Pressure 0 4kpa 3mmHg Pulse value 5 WARRANTY AMG Medical Inc warrants this product to be free from defects in material and workmanship for a period of two 2 years This warran...
Page 14: ...is product please call www amgphysiologic com 1 800 363 2381 CONTACT INFORMATION 24 Physio logic essentia Manual ENG 106 930 921 106930E 21 5 cm x 14 5 cm 21 5 x 14 5 cm folded 10 75 x 14 5 c Instruct...