32
Fault Code Chart
Error Code
Description of Error
Diagnostic Instruction & Correct Action & Repair
E00
Communications Error
Check all wiring to heater.
Reboot ECU by removing main fuse for 5 minutes.
Replace ECU as necessary
E01
Failed Ignition
(Two attempts)
Heater does not start successfully within start up period.
Refer to Combustion Issues in manual.
E02
Flame Extinguished
(Three successive failures)
Heater establishes a flame then detects a flame out condition.
Refer to Combustion Issues in manual.
E03
High or Low Voltage
Voltage at ECU must be less than 16.0 volts and more than 10.5 volts
Repair vehicle electrical system as required
E04
Premature Ignition
Heater detect flame prior to fuel pump operation.
Unburnt fuel in combustion chamber during start up.
Refer to Combustion Issues in manual.
E05
Thermal Efficiency Failure
Heater detects a poor combustion
Refer to Combustion Issues in manual.
E06
Temperature Sensor Open or Short Circuit
Check sensor resistance.
Should be approximately 1.0 kΩ at room temp. Replace as necessary
E07
Fuel Pump
Open / Short Circuit
Check fuel pump wiring connections & resistance across fuel pump terminals
and main harness pins 10 & 11. Should be 7.5-8.5 Ω
Repair wiring or replace fuel pump as required
E08
Blower Motor
Open / Short Circuit or blockage
Check blower motor wiring & blower motor for free rotation
Repair wiring or replace blower as required
E09
Glow Pin
Short Circuit
Check glow pin connectors and resistance across glow pin
Should be 0.8 Ω. Replace glow pin as required.
E10
Over Temperature
Check fan operation & for blockage of hot air ducting air flow
(in and out)
Check Flame / Overheat sensor resistance.
Should be approximately 1.0 kΩ at room temp. Replace as necessary
E11
Temperature Sensor
Short Circuit
Check Temperature sensor resistance.
Should be approximately 1.0 kΩ at room temp. Replace as necessary
E12
Glow Pin
Open Circuit
Check glow pin connectors and resistance across glow pin
Should be 0.8 Ω. Replace glow pin as required.
E14
Temperature Sensor
Open Circuit
Check positioning of sensor to ensure proper contact with heat exchanger
Check Temperature sensor resistance.
Should be approximately 1.0 kΩ at room temp. Replace as necessary
E15
Open Circuit in Operating Switch potentiometer
Replace operating switch.