31
FASTCAM SA8 Hardware Manual
3.10.5. GENERAL IN Connector
The effect when a signal is input is described below, and can be optionally selected and set. The
setting is made from the PFV.
The input voltage is 0V to +12V (L level +1.0 or less, H level +2.8V to +12V), positive or negative
polarity, pulse width is 100 ns or greater.
TRIG POS/NEG
Inputs a TTL trigger signal.
READY POS/NEG
Inputs a change recording ready status signal (READY ON/OFF).
To make the setting from PFV, refer to the “Photron FASTCAM Viewer User’s Manual”.
3.10.6. GENERAL OUT (1, 2) Connector
These are also BNC connectors. The signals below can be changed and output from the PFV.
(POS: positive polarity, NEG: negative)
SYNC POS/NEG
Outputs a vertical synchronization signal.
EXPOSE POS/NEG
Outputs the camera's exposure period signal.
* Outputs during both LIVE and recording.
REC POS/NEG
Outputs a signal during recording.
TRIG POS/NEG
Outputs the trigger signal the camera received.
READY POS/NEG
Outputs a signal that indicates the recording ready state.
Refer to “3.13.2. GENERAL OUT Signal Settings”, page 40 for details.
Summary of Contents for FASTCAM SA7
Page 1: ...F FA AS ST TC CA AM M S SA A8 8...
Page 11: ......
Page 15: ...1 FASTCAM SA8 Hardware Manual Chapter 1 Overview 1 1 Product Overview and Features...
Page 47: ...33 FASTCAM SA8 Hardware Manual TRIG TTL IN GENERAL TTL IN TRIG SW IN Circuit Diagram...
Page 60: ...Chapter 3 Recording 46...
Page 69: ...55 FASTCAM SA8 Hardware Manual...
Page 77: ...63 FASTCAM SA8 Hardware Manual...
Page 81: ...67 FASTCAM SA8 Hardware Manual 5 2 5 Remote Keypad Option mm 167 9 105 4 155 4 28 2 29 7000...
Page 82: ...Chapter 5 Product Specifications 68...
Page 83: ...69 FASTCAM SA8 Hardware Manual Chapter 6 Warranty 6 1 About the Warranty...
Page 85: ...71 FASTCAM SA8 Hardware Manual Chapter 7 Contacting Photron 7 1 Contact Information...