background image

 

Scanning Parameters - Model XS 

Parameter 

Value 

Resolution 

Up to 3.2 Million 3D points 

Scanning range 

161 - 205 mm 

Optimal scanning distance (focus) 

181 mm 

Scanning area (at focus distance) 

113 x 83 mm 

Point to point distance (at focus distance) 

0.055 mm 

Calibration accuracy 

0.035 mm 

Temporal noise 

0.03 mm 

Scanning time 

250 - 2000 ms 

Dimensions 

77 x 68 x 296 mm 

Baseline 

85 mm 

Weight 

900 g 

3D point throughput 

16 Million points per second 

 

These parameters are valid at 25 °C, at focus distance for white objects with 80 % albedo. 

 

 

01/2020

PhoXi 3D Scanner XS - Quick Start Guide

2/8 

Summary of Contents for PhoXi 3D Scanner XS

Page 1: ...ated by the PhoXi Control application PhoXi Control allows the user to control the scanner either manually through a graphical user interface or programmatically through the provided API All PhoXi Con...

Page 2: ...13 x 83 mm Point to point distance at focus distance 0 055 mm Calibration accuracy 0 035 mm Temporal noise 0 03 mm Scanning time 250 2000 ms Dimensions 77 x 68 x 296 mm Baseline 85 mm Weight 900 g 3D...

Page 3: ...Scanning Volume Model XS 01 2020 PhoXi 3D Scanner XS Quick Start Guide 3 8...

Page 4: ...o avoid vibrations during scanning Allow clearance of 25 mm for natural convection cooling The ambient temperature range for the scanner operation is 0 C to 30 C Separate the scanner from high voltage...

Page 5: ...plied power adapter The I O ports are reserved for future use Ethernet Pinout Power Pinout Pin Pinout Pin Pinout 1 MD1_P 1 IN2 laser interlock 5 12 V 2 12V_IN 2 IN1 3 MD2_N 3 OUT2 4 MD2_P 4 OUT1 5 MD0...

Page 6: ...Status LEDs The LEDs indicate the following states of the scanner Supported Network Topologies 01 2020 PhoXi 3D Scanner XS Quick Start Guide 6 8...

Page 7: ...e to oils water and UV Custom Cables In case custom cables are used the voltage must reach 12 V at the device end Longer custom cables should have wires of a larger diameter to compensate for voltage...

Page 8: ...Do not deliberately look into the laser beam This may cause injury to the retina Laser protective eyewear is normally not necessary Contact Us Headquarters Photoneo s r o Plynarenska 1 82109 Bratislav...