Fig. 9 Finishing. 

 

On computer run the program FluorPen 1.1. For more information about FluorPen software see chapter 10. 

 

Summary of Contents for N-Pen N 110

Page 1: ...N Pen N 110 Manual and User Guide Please read this manual before operating this product PSI spol s r o Dr sov 470 664 24 Dr sov Czech Republic FAX 420 511 440 901 TEL 420 511 440 011 www psi cz...

Page 2: ...respond to the specifications of the device However deviations cannot be ruled out Therefore a complete correspondence between the manual and the real device cannot be guaranteed The information in th...

Page 3: ...PSI Photon Systems Instruments spol s r o 3...

Page 4: ...2 7 1 Measurement 12 8 Control Menu Tree 13 9 USB and Bluetooth Connection 18 9 1 USB Connection 18 9 2 Bluetooth Connection 19 9 3 Bluetooth Pairing 19 10 FluorPen Software 23 10 1 Software Installat...

Page 5: ...rees to follow the instructions in this guide Always follow corresponding manuals while working with the N Pen device or doing the maintenance It is forbidden to interfere with the hardware or softwar...

Page 6: ...ape Time Turns off after 8 minutes of no use Power Supply Li Ion rechargeable battery Battery Capacity 2000 mAh Max Charging Current 0 5 A Charging via USB port PC power bank USB charger etc Battery L...

Page 7: ...ged and compact N Pen can be used for plant biology research or for education Due to an inbuilt GPS module and splash proof cover is N Pen suitable for field experiments The measurement is non destruc...

Page 8: ...PSI Photon Systems Instruments spol s r o 8 3 1 DEVICE DESCRIPTION Fig 1 Device description...

Page 9: ...res according to your specific order For USB connection you need to have the USB driver installed in your PC You find the driver on the installation disk USB driver folder If any item is missing pleas...

Page 10: ...ever submerge the whole device in the water Keep the optical part clean and dry Inspect visually the optical window after each deployment Use soft non abrasive tissue for cleaning the optical part The...

Page 11: ...asurements You can change number of measurements from 6 to 20 For example after perform a series of 10 measurements the average value of nitrogen content is automatically determined and displayd in Th...

Page 12: ...to measure other samples It is necessary to calibrate N Pen after every switch ON Before performing the calibration make sure that the optical part of the device including the inner part of the sampl...

Page 13: ...re of the operation scheme which includes the Main Menu and first level Sub Menus The blue color represents the Main Menu and its Options The yellow color represents the first level Sub Menus and thei...

Page 14: ...PSI Photon Systems Instruments spol s r o 14...

Page 15: ...PSI Photon Systems Instruments spol s r o 15...

Page 16: ...PSI Photon Systems Instruments spol s r o 16...

Page 17: ...PSI Photon Systems Instruments spol s r o 17...

Page 18: ...let part on the USB cable C E Position the cable horizontally plug in the inlet and screw the securing screw F Correct connection of the USB cable and Pen device Connect the USB cable to a computer Th...

Page 19: ...se consult your PC s Bluetooth documentation for more information 3 Bluetooth must be switched on visible on both devices To pair the N Pen with another Bluetooth device such as a computer you will ne...

Page 20: ...ation 3 Opening the Add Bluetooth Device Application Select Add a device to start searching new Bluetooth device Be sure that the N Pen is in discoverable mode see step 1 Fig 5 Add a device 4 Selectin...

Page 21: ...pairing code Enter 0000 four digits Select Next Fig 7 Fig 7 Pairing process New version Select Yes Fig 8 Please note that the N Pen device does not display the verification number The verification co...

Page 22: ...PSI Photon Systems Instruments spol s r o 22 Fig 9 Finishing On computer run the program FluorPen 1 1 For more information about FluorPen software see chapter 10...

Page 23: ...Select OK Fig 10 Software registration Please note that you will find your serial registration number in the file SN txt which is included on the enclosed USB flash disk Please remember it is not pos...

Page 24: ...ata in txt format Export to JSON Exports data in JavaScript Object Notation Close Closes the current experiment Close All Closes all running experiments Exit Exits the program MENU Device Download Dow...

Page 25: ...ad Memory Erase If the box is checked the N Pen memory is erased after each data download Data Inverted If the box is checked the polarity of data is inverted e g multiplied by 1 This feature can be h...

Page 26: ...ilable for N Pen device 10 2 3 MENU ONLINE CONTROL This function can be used for Online Control your N Pen device after connection with your PC Select Menu Device Online Control Online Control Switche...

Page 27: ...n Systems Instruments spol s r o 27 10 3 DATA TRANSFER 1 Perform a measurement with your N Pen 2 Click the Download icon or select Device Download 3 The Data table appears Fig 12 Fig 12 Example of Dat...

Page 28: ...export Fig 13 Selected only exports only one measurement that is selected by mouse otherwise it will export everything Source data exports raw data in case of nitrogen content NDGI Description exports...

Page 29: ...pdate Before starting any firmware update export all your data from the N Pen memory into your computer 1 Starting Update Select Setup Update Firmware From File Fig 14 Fig 14 Update Firmware 2 Warning...

Page 30: ...Fig 16 Select bxn file 4 Finishing Upload Select OK to start uploading of the update Fig 17 Fig 17 Finishing upload The bottom bar indicates the upload progress Fig 18 Fig 18 Upload progress Press OK...

Page 31: ...the time setting in N Pen device Settings Date Time 2 Switch the GPS module on Select Accessories GPS Press SET to confirm Wait until the GPS position is found Starting GPS The GPS module is ready wh...

Page 32: ...our computer to N Pen communication enable Bluetooth or connect to USB port 2 Downloading Data from the N Pen Start FluorPen program Connect N Pen device Setup Device ID Ctrl I Download measured data...

Page 33: ...nufacturer The warranty is return to base only and does not include on site repair charges such as labor travel or other expenses associated with the repair or installation of replacement parts at the...

Page 34: ...Systems Instruments spol s r o 34 13 TROUBLESHOOTING AND CUSTOMER SUPPORT In case of troubles and for customer support please visit FAQ on our websites write to support psi cz or contact your local d...