6.1 Counter
Counter Trigger Source
6
=
Off
The state of the counter changes to "trigger wait".
The counter reset source can be set to the counter end signal of the same
counter. This allows to restart the counter automatically as soon as it arrives
its end condition.
The current counter value at the time, when the reset is performed, is stored to the
CounterValueAtReset property, which can be read out by software.
6.1.5
Counter Event Source
The counter event source selects the signal event, which will be the used to increment the
counter. The following signal sources are available:
Off
Counter is idle or has been stopped temporarely and doesn’t count any events.
Acquisition Trigger
Counts the number of acquisition triggers.
Acquisition Start
Counts the number of acquisition start events.
Acquisition End
Counts the number of acquisition end events.
FrameTrigger
Counts the number of frame triggers.
Frame Start
Counts the number of frame start events.
Frame End
Counts the number of frame end events.
Frame Burst Start
Counts the number of frame burst start events.
Frame Burst End
Counts the number of frame burst end events.
Exposure Start
Counts the number of exposure start events.
Exposure End
Counts the number of exposure end events.
Counter 0 ... 3 Start
Counts the number of the chosen counter start events.
Counter 0 ... 3 End
Counts the number of the chosen counter end events.
Timer 0 ... 3 Start
Counts the number of the chosen timer start events.
Timer 0 ... 3 End
Counts the number of the chosen timer end events.
Encoder
Counts the number of the encoder trigger events.
Action 0 ... 3
Counts the number of the chosen action signal events.
Software Signal Pulse 0 ... 7
Counts the number of the chosen software signal pulse events
(see Section 4.7).
Line Input
Counts the number of transitions on the line input according to the signal input
activation configuration.
MissedAcqStartTrigger
Count the number of missed acquisition start triggers. A missed
acquisition start trigger event is generated, when a acquisition start trigger cannot be
processed.
MissedFrameStartTrigger
Count the number of missed frame start triggers. A missed frame
start trigger event is generated, when a frame start trigger cannot be processed.
MAN093 08/2021 V1.1
45 of 143
Summary of Contents for MV4 Series
Page 8: ...CONTENTS 8 of 143 MAN093 08 2021 V1 1 ...
Page 12: ...1 Preface 12 of 143 MAN093 08 2021 V1 1 ...
Page 40: ...4 Image Acquisition 40 of 143 MAN093 08 2021 V1 1 ...
Page 42: ...5 Exposure Control 42 of 143 MAN093 08 2021 V1 1 ...
Page 52: ...6 Counter Timer 52 of 143 MAN093 08 2021 V1 1 ...
Page 64: ...10 Image Format Control 64 of 143 MAN093 08 2021 V1 1 ...
Page 66: ...11 Frame Rate 66 of 143 MAN093 08 2021 V1 1 ...
Page 82: ...12 Pixel Data Processing 82 of 143 MAN093 08 2021 V1 1 ...
Page 92: ...12 Pixel Data Processing 92 of 143 MAN093 08 2021 V1 1 ...
Page 96: ...13 Precautions 96 of 143 MAN093 08 2021 V1 1 ...
Page 120: ...16 Troubleshooting 120 of 143 MAN093 08 2021 V1 1 ...
Page 126: ...19 Support and Repair 126 of 143 MAN093 08 2021 V1 1 ...
Page 128: ...20 References 128 of 143 MAN093 08 2021 V1 1 ...