grabber.
A possible origin of failure can be a CameraLink cable which exceeds the maxi-
mum length or suffers from severe electromagnetic interference.
Some CameraLink cables have a predefined direction.
Figure 4.13: LFSR test pattern received at the frame grabber and typical histogram for error-free data
transmission
The LFSR test works only for an image width of 1024, otherwise the histogram
will not be flat.
Figure 4.14: LFSR test pattern received at the frame grabber and histogram containing transmission errors
CameraLink cables contain wire pairs, which are twisted in such a way that the
cable impedance matches with the LVDS driver and receiver impedance. Excess
stress on the cable results in transmission errors which causes distorted images.
Therefore, please do not overly stretch and bend CameraLink cables during in-
stallation and operation.
4.3 Pixel Response
29