5 Functionality
The setting
Counter_ResetCounterMode
=
Continuous
resets the counters on every occurrence of an
active edge of the reset source without the requirement to arm the device first. This setting is
suited if the reset source signal is different than the camera trigger.
The active edge of the reset input can be set by the property
Counter_ResetCounterSourceInvert
.
If set to
True
, then the rising edge is the active edge, else the falling edge.
Counter reset by an external signal is important if you would like to synchronize
multiple cameras. One signal is applied to all cameras which resets the coun-
ters simultaneously. The timestamps of all cameras are then theoretically syn-
chronous with each other. In practice every camera runs on its own clock source
which has a precision of +/- 30 ppm and therefore the values of the timestamp
(real time counter) of the cameras may diverge with time. If this is an issue, then
the counters could be reset periodically by the external signal.
The counter reset by an external signal feature is not available on all camera
revisions, see Appendix B for a list of available features.
Reset of Individual Counters (ResetCounter_Dual)
If the property ResetCounter_Dual is set to False or if this property is not available, then the
ResetCounter settings apply to the image counter and to the real time counter together.
If ResetCounter_Dual is set to True then CounterReset can be set separately for the image
counter and for the real time counter. In this case the settings without ’RTC’ are applied to the
image counter and the settings with ’RTC’ in its name are applied to the real time counter.
The
ResetCounter_Dual
feature is not be available on all camera revisions, see
Appendix B for a list of available features.
.
56 of 123
MAN069 12/2018 V1.1
Summary of Contents for MV1-D4096 Series
Page 1: ...Photonfocus MV1 D4096 Camera Series CMOS camera with GigE interface MAN069 12 2018 V1 1 ...
Page 10: ...1 Preface 10 of 123 MAN069 12 2018 V1 1 ...
Page 12: ...2 Introduction 12 of 123 MAN069 12 2018 V1 1 ...
Page 32: ...4 Product Specification 32 of 123 MAN069 12 2018 V1 1 ...
Page 94: ...6 Hardware Interface 94 of 123 MAN069 12 2018 V1 1 ...
Page 108: ...7 Software 108 of 123 MAN069 12 2018 V1 1 ...
Page 110: ...8 Mechanical Considerations 110 of 123 MAN069 12 2018 V1 1 ...
Page 112: ...9 Troubleshooting 112 of 123 MAN069 12 2018 V1 1 ...
Page 118: ...12 Support and Repair 118 of 123 MAN069 12 2018 V1 1 ...
Page 120: ...13 References 120 of 123 MAN069 12 2018 V1 1 ...
Page 124: ...B Camera Revisions 124 of 123 MAN069 12 2018 V1 1 ...