
5.2 Trigger and Strobe
5.2.9
A/B Trigger for Incremental Encoder
An incremental encoder with A/B outputs can be used to synchronize the camera triggers to
the speed of a conveyor belt. These A/B outputs can be directly connected to the camera and
appropriate triggers are generated inside the camera.
The A/B Trigger feature is is not available on all camera revisions, see Appendix
B for a list of available features.
In this setup, the output A is connected to the camera input ISO_INC0 (see also Section 6.5.4
and Section A.1) and the output B to ISO_INC1.
In the camera default settings the PLC is configured to connect the ISO_INC inputs to the A/B
camera inputs. This setting is listed in Section 7.9.3.
The following parameters control the A/B Trigger feature:
TriggerSource
Set TriggerSource to
ABTrigger
to enable this feature
ABMode
Determines how many triggers should be generated. Available modes: single,
double, quad (see description below)
ABTriggerDirection
Determines in which direction a trigger should be generated:
fwd
: only
forward movement generates a trigger;
bkwd
: only backward movement generates a
trigger;
fwdBkwd
: forward and backward movement generate a trigger.
ABTriggerDeBounce
Suppresses the generation of triggers when the A/B signal bounce.
ABTriggerDeBounce is ignored when
ABTriggerDirection
=
fwdbkwd
.
ABTriggerDivider
Specifies a division factor for the trigger pulses. Value 1 means that all
internal triggers should be applied to the camera, value 2 means that every second
internal trigger is applied to the camera.
EncoderPosition (read only)
Counter (signed integer) that corresponds to the position of
incremental encoder. The counter frequency depends on the ABMode. It counts up/down
pulses independent of the
ABTriggerDirection
. Writing to this property resets the counter
to 0.
A/B Mode
The property ABMode takes one of the following three values:
Single
A trigger is generated on every A/B sequence (see Fig. 5.16).
TriggerFwd
is the trigger
that would be applied if
ABTriggerDirection
=
fwd
,
TriggerBkwd
is the trigger that would be
applied if
ABTriggerDirection
=
bkwd
,
TriggerFwdBkwd
is the trigger that would be applied if
ABTriggerDirection
=
fwdBkwd
.
GrayCounter
is the Gray-encoded BA signal that is shown as an
aid to show direction of the A/B signals.
EncoderCounter
is the representation of the
current position of the conveyor belt. This value is available as a camera register.
Double
Two triggers are generated on every A/B sequence (see Fig. 5.17).
Quad
Four triggers are generated on every A/B sequence (see Fig. 5.18).
.
MAN069 12/2018 V1.1
51 of 123
Summary of Contents for MV1-D4096 Series
Page 1: ...Photonfocus MV1 D4096 Camera Series CMOS camera with GigE interface MAN069 12 2018 V1 1 ...
Page 10: ...1 Preface 10 of 123 MAN069 12 2018 V1 1 ...
Page 12: ...2 Introduction 12 of 123 MAN069 12 2018 V1 1 ...
Page 32: ...4 Product Specification 32 of 123 MAN069 12 2018 V1 1 ...
Page 94: ...6 Hardware Interface 94 of 123 MAN069 12 2018 V1 1 ...
Page 108: ...7 Software 108 of 123 MAN069 12 2018 V1 1 ...
Page 110: ...8 Mechanical Considerations 110 of 123 MAN069 12 2018 V1 1 ...
Page 112: ...9 Troubleshooting 112 of 123 MAN069 12 2018 V1 1 ...
Page 118: ...12 Support and Repair 118 of 123 MAN069 12 2018 V1 1 ...
Page 120: ...13 References 120 of 123 MAN069 12 2018 V1 1 ...
Page 124: ...B Camera Revisions 124 of 123 MAN069 12 2018 V1 1 ...