![Photon Focus MV1-D2048-3D06 series User Manual Download Page 74](http://html1.mh-extra.com/html/photon-focus/mv1-d2048-3d06-series/mv1-d2048-3d06-series_user-manual_1553550074.webp)
5 Functionality
Missed FrameCombine trigger counter
Counts missed triggers due to the FrameCombine
feature (see also Section 5.2.9). A missed FrameCombine trigger can occur if a trigger is
applied while filler rows are added to a frame due to a FrameCombine timeout.
5.10.2
Status Information
Status information is inserted in the 4 LSB in the last 3D data row if DataFormat3D = 3 or 4 (see
bits labeled STAT in Fig. 5.8). LSB are transmitted first (see Table 5.8). The status information is
divided in fields of 32 bits each, where every information field corresponds to one information
parameter (see Table 5.9). Unused bits are set to 0.
Col 0
Col 1
Col 2
Col 3
...
Col n
STAT[3:0]
STAT[7:4]
STAT[11:8]
STAT[15:12]
...
STAT[4*n+3:4*n]
Table 5.8: STAT value
.
74 of 127
MAN075 05/2017 V1.0