Look-Up-Table
Grey level transformation is remapping of the grey level values of an input image to new
values which transform the image in some way. The look-up-table (LUT) is used to convert the
greyscale value of each pixel in an image into another grey value. It is typically used to
implement a transfer curve for contrast expansion.
The MV-D1024E-3D01-160 camera performs a 10-to-8-bit mapping, so that 1024 input grey
levels can be mapped to 256 output grey levels (0 to 1023 and 0 to 255).
The default LUT is a gain function with value = 1.
Lut Mode:
Gain:
Linear function. Y = 255 / 1023 * value * X; Valid range for
value
[1...4].
Gamma:
Gamma function. Y = 255 / 1023^value * X ^ value; Valid range for
value
[0.4...4].
value:
Enter a value. The LUT will be calculated and downloaded to the camera.
Load File...:
Load a user defined LUT - file into the camera (*.txt tab delimited). There is an
example in the PFRemote directory (mv_d1024e_3d01_160_lut.txt).
Save File...:
Save LUT from camera into a file.
It is also possible to load a user LUT-file with missing input values (LUT-addresses). Then only
pixel values corresponding to listed LUT entries will be overwritten. Example of a user defined
LUT file:
Figure 7.6: Example of a user defined LUT file
76
Summary of Contents for MV-D1024E-3D01-160
Page 1: ...User Manual MV D1024E 3D01 160 3D CMOS Camera MAN037 04 2009 V1 1...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 20: ...3 Product Specification 18...
Page 57: ...5 2 CameraLink Data Interface 55...
Page 66: ...5 Hardware Interface 64...
Page 84: ...7 Graphical User Interface GUI 82...
Page 90: ...9 Warranty 88...
Page 92: ...10 References 90...
Page 96: ...A Pinouts 94...