Phono Solar Standard PV Modules with the Model Names covered under this warranty are:  
PSXXXM-24/F (XXX = 180, 185, 190, 195,200,205,210)
PSXXXM-20/U (XXX = 230,235,240,245,250,255,260,265,270)
PSXXXP-20/U (XXX = 230,235,240,245,250,255,260,265)
PSXXXM-24/T (XXX = 280,290,300,310,320,330) 
PSXXXP-24/T (XXX = 280,290,300,310,320,330) 

The product (hereinafter the “Product”) in this Warranty means the Standard PV Module(s) 
manufactured  by  Phono  Solar  Technology  Co.,  Ltd.  (hereinafter  the  “Phono  Solar”).  The 
Phono  Solar  warrants  its  Product(s)  in  compliance  with  the  terms  and  conditions  as 
stipulated below. 

The Customer in this Warranty means the individual person or company who purchases 
Phono Solar Product. 

This “Limited Warranty for PV-Modules“ is valid for all Standard Modules delivered from 
Phono Solar since January 

1

st

, 2015

Phono Solar warrants that the Product including factory-assembled DC connectors and 
cables, if any, will be free from defects in material and workmanship under normal 
application, installation, operation, use and service conditions. If Product fails to 
conform to this warranty, within a period of ten (10) years from the date of delivery 
by Phono Solar to its first buyer, Phono Solar will, at its sole discretion, either 
repair the defective Product(s) at no charge; or replace the defective Product(s) or 
part thereof by a new or remanufactured equivalent at no charge, within the above 
specified period. This repair or replacement remedy shall be the sole and exclusive 
remedy provided under the “Limited Product Warranty” and shall not extend beyond 
the ten years period set forth herein. 
This “Limited Product Warranty” does not warrant a specific power output, which shall 
be exclusively covered under clause 2 hereinafter (“Limited Peak Power Warranty”).

Limited Product Warranty –Repair or Replacement

Ten (10) years 

Limited Warranty for PV-Modules

DISCLAIMER OF LIABILITY

Since it is impossible for PHONO SOLAR to control installation, operation, application 
and  maintenance  of  the  photovoltaic  system  according  to  this  instruction,  PHONO 
SOLAR  does  not  accept  responsibility  and  expressly  disclaims  liability  for  any  loss, 
damage,  or  expense  arising  out  of  or  in  any  way  connected  with  such  installation, 
operation, use or maintenance.

PHONO SOLAR will not take any responsibilities for any possible violation of patent 
rights and third party rights that are related to application of the solar energy system. 
No permission of patents is given through implication.

The  information  of  this  instruction  is  from  knowledge  and  experience  of  PHONO 
SOLAR,  and  so  it  is  reliable.  However,  the  instructions  and  suggestions  of  this 
instruction do not make an external or internal of guarantee. PHONO SOLAR reserves 
the  right  to  revise  this  instruction,  products  and  all  the  information  about  products 
without prior notification to customers.

6

 MAINTENANCE

In  order  to  ensure  optimum  module  performance,  PHONO  SOLAR  recommends  the 
following:

6.1   

If  necessary,  the  glass  front  of  the  module  can  be  cleaned  with  water  and  a 

soft  sponge  or  cloth.  A  mild,  non-abrasive  detergent  can  be  used  to  remove  more 
stubborn stains.

6.2  

Check the electrical and mechanical connections periodically and make sure they 

are clean, safe, complete and secure.

6.3  

In the event of a problem, consult with a licensed/qualified person.

Summary of Contents for F Type module

Page 1: ...lation Manual UL Phono Solar Technology Co Ltd Address No 1 Xinghuo Rd Nanjing Hi tech Zone Nanjing China Tel 86 25 5863 8000 Fax 86 25 5863 8009 E mail support phonosolar com Website www phonosolar c...

Page 2: ...1 IMPORTANT SAFETY GUIDE 2 PRODUCT IDENTIFICATION 3 MECHANICAL INSTALLATION 4 ELECTRICAL INSTALLATION 5 GROUDING 6 MAINTENANCE 7 DISCLAIMER OF LIABILITY CONTENTS...

Page 3: ...aic modules hereafter referred to as module supplied by PHONO SOLAR TECHNOLOGY CO LTD hereafter referred to as PHONO SOLAR The term module can be interpreted as a single module or multiple modules dep...

Page 4: ...n be used to cover the modules Only use licensed qualified insulated tools The frame of the modules may be grounded according to local regional and state safety and electrical standards Only Balance o...

Page 5: ...posed between the two metals When grounding the module frames stainless steel hardware must also be used Note2 In environments where ammonia is present Phono Solar PV modules must be installed under t...

Page 6: ...U Type 1640mm 992mm 35 40 45mm DIAMOND Series ONYX Series T Type 1956mm x 992mm x 45 50mm DIAMOND Series ONYX Series Module Frame Mounting Rail M8 Screw Split Washer M8 Bolt M8 Nut Flat Washer Mounti...

Page 7: ...ility Reliability Creativity B B 410 490mm B B A A 300mm Mounting rails may run perpendicularly or parallel to the long side frame A A Mounting rails may run perpendicularly or parallel to the long si...

Page 8: ...s will void the PHONO SOLAR product warranty 3 4 When installing a module on a pole ensure that the pole and mounting rail can withstand anticipated local winds The pole must be installed on a hard ba...

Page 9: ...ranty and shall not extend beyond the ten years period set forth herein This Limited Product Warranty does not warrant a specific power output which shall be exclusively covered under clause 2 hereina...

Page 10: ...ars from the date of delivery by Phono Solar to the first buyer any Product exhibits a power output less than 80 of the minimum Peak Power at STC 1 as specified as of the Phono Solar s product label p...

Page 11: ...st extent permitted by law Phono Solar shall have no responsibility or liability whatsoever for damage or injury to persons or property or for other loss or injury resulting from any cause whatsoever...

Page 12: ...ation of 1000 W per m2 and c a cell temperature of 25 degree centigrade at right angle irradiation The measurements are carried out in accordance with IEC 61215 as tested at the connectors or junction...

Reviews: