background image

04

05

Stability / Reliability / Creativity

PRODUCT IDENTIFICATION

On the back of each module there are 2 labels that provide the following information:

Nameplate: 

Describes the product type, rated power, rated current, rated voltage, open 

circuit voltage, short circuit current, all as measured under STC; weight, dimensions etc.; 
the maximum system voltage of 1000V DC. 

 

Warning: The value of Voc times the number of modules in series should  

 

not be bigger than the maximum system voltage marked in the nameplate.

Barcode: 

This is used to identify each module. Each module has a unique and traceable 

serial number in the form of barcode. The barcode of each PHONO SOLAR module has 
15 letter/digits. 

 

Warning: Do not remove the nameplate or barcode. The PHONO SOLAR product

 

warranty will be void if either the module nameplate or barcode is removed.

MECHANICAL INSTALLATION

(Note:  All  instructions  hereafter  are  for  reference  only.    A  licensed/qualified 
person or installer must be responsible for the design, installation, mechanical 
load calculation and security of the photovoltaic system.)

In saline environments, Phono Solar PV modules must be installed under the following 
conditions:
   Modules shall not be installed in locations where they will come into direct contact   
    with salty water, that is, in offshore (e.g. platforms) and marine (e.g. piers, boats)    
    applications.
   Modules installed in locations where the distance from the sea is less than 500 m  
    shall fulfill the following requirements:
   The modules shall be mounted with a minimum tilt angle of 10° in respect to the horizon;
   When fixing the modules using the 8 mounting slots, all the hardware (washers,
    screws and nuts) shall be made of stainless steel;
   To avoid possible galvanic corrosion between the aluminum frame and the support  
    structure, PVC washers or neoprene tape shall be interposed between the two metals;
   When grounding the module frames, stainless steel hardware must also be used.

Note

2

In  environments  where  ammonia  is  present,  Phono  Solar  PV  modules  must  be 

installed under the following conditions: 
   When fixing the modules using the 8 mounting slots, all the hardware (washers,
    screws and nuts) shall be made of stainless steel;
   To avoid possible galvanic corrosion between the aluminum frame and the support  
    structure, PVC washers or neoprene tape shall be interposed between the two metals;
   When grounding the module frames, stainless steel hardware must also be used. 

3.2  Select suitable mounting rails

 Please observe the safety regulations and installation instructions included with the 

mounting rail. If necessary please contact the supplier directly for further information.

 The modules must be safely set onto the mounting rail. The whole rail supporting the 

photovoltaic  system  must  be  strong  enough  to  resist  potential  mechanical  pressures 

caused either by wind or snow, in accordance with local, regional and state safety (and 

other associated) standards.

  Make  sure  that  the  mounting  rail  will  not  deform  or  affect  the  modules  when  it 

expands as a result of thermal expansion.

 The mounting rail must be made of durable, anti-corrosive and UV-resistant materials.

3.1  Select suitable locations for installation

 Select a suitable location for installing the modules. 
  PHONO  SOLAR  recommends  that  to  achieve  the  best  performance  the  modules 

should face south in northern latitudes and north in southern latitudes. The exact tilt 
angle and orientation of mounted modules should be recommended by a licensed/
qualified installer.

 The modules should be completely free of shade at all times.
  Do  not  place  the  modules  near  a  location  where  flammable  gases  are  either 

generated or collected.

Note

1

:

 Saline environments can accelerate the processes of electrical insulation losses 

and  galvanic  corrosion,  especially  when  different  metals  with  high  electrochemical 
potential come into contact each other. 

Summary of Contents for F Type module

Page 1: ...lation Manual UL Phono Solar Technology Co Ltd Address No 1 Xinghuo Rd Nanjing Hi tech Zone Nanjing China Tel 86 25 5863 8000 Fax 86 25 5863 8009 E mail support phonosolar com Website www phonosolar c...

Page 2: ...1 IMPORTANT SAFETY GUIDE 2 PRODUCT IDENTIFICATION 3 MECHANICAL INSTALLATION 4 ELECTRICAL INSTALLATION 5 GROUDING 6 MAINTENANCE 7 DISCLAIMER OF LIABILITY CONTENTS...

Page 3: ...aic modules hereafter referred to as module supplied by PHONO SOLAR TECHNOLOGY CO LTD hereafter referred to as PHONO SOLAR The term module can be interpreted as a single module or multiple modules dep...

Page 4: ...n be used to cover the modules Only use licensed qualified insulated tools The frame of the modules may be grounded according to local regional and state safety and electrical standards Only Balance o...

Page 5: ...posed between the two metals When grounding the module frames stainless steel hardware must also be used Note2 In environments where ammonia is present Phono Solar PV modules must be installed under t...

Page 6: ...U Type 1640mm 992mm 35 40 45mm DIAMOND Series ONYX Series T Type 1956mm x 992mm x 45 50mm DIAMOND Series ONYX Series Module Frame Mounting Rail M8 Screw Split Washer M8 Bolt M8 Nut Flat Washer Mounti...

Page 7: ...ility Reliability Creativity B B 410 490mm B B A A 300mm Mounting rails may run perpendicularly or parallel to the long side frame A A Mounting rails may run perpendicularly or parallel to the long si...

Page 8: ...s will void the PHONO SOLAR product warranty 3 4 When installing a module on a pole ensure that the pole and mounting rail can withstand anticipated local winds The pole must be installed on a hard ba...

Page 9: ...ranty and shall not extend beyond the ten years period set forth herein This Limited Product Warranty does not warrant a specific power output which shall be exclusively covered under clause 2 hereina...

Page 10: ...ars from the date of delivery by Phono Solar to the first buyer any Product exhibits a power output less than 80 of the minimum Peak Power at STC 1 as specified as of the Phono Solar s product label p...

Page 11: ...st extent permitted by law Phono Solar shall have no responsibility or liability whatsoever for damage or injury to persons or property or for other loss or injury resulting from any cause whatsoever...

Page 12: ...ation of 1000 W per m2 and c a cell temperature of 25 degree centigrade at right angle irradiation The measurements are carried out in accordance with IEC 61215 as tested at the connectors or junction...

Reviews: