PHONIX MS 1002 User Manual Download Page 8

MS 1002  - 9

MS 1002

If you want to change settings in "Programm 2"
and "Programm 3" then repeat the Steps 1 to 3
by pressing the corresponding button. The tem-
perature setting is changed in 1°C steps.

Positioning "späteres Startens" (=”starting
later”)

At factory setting the time for starting later (spä-
teres Starten) is 0 minutes The delay you want
the machine starting later is expressed in hours
and minutes For example 9:45 means that 9
hours and 45 minutes will pass before the was-
hing machine will start.
If you want to change the time please do the fol-
lowing:

1. Press and hold button "späteres Starten".
2. Change value by pressing b/- in 

steps of 5 minutes.

3. Release buttons and press "Stop".

The programmed value is the same for "Pro-
gramm 1", "Programm 2 and "Programm 3". 

If “starting later” is active you can see a clock in
the display. If you want to activate starting later
press the button "späters Starten". If you want
to start the machine immediatly after you´ve first
time pressed the button press button a second
time. (There will be no more clock showed in the
display).

Turning into the emergency program 

(device

switches into the emergency program after a
blackout itself)
If there is a error or defect part at any time, you
can turn the Ms1002 into a emergency program,
so you can use your washing machine, like the
MS1002 weren´t installed. In this program the
cold water valve is open and the power is
always on. 
To activate the emergency program, just press
the buttons "Programm 1", "Programm 2" and

"Programm3" at the same time.

Reset

With that, all parameter will be restored
to the default settings.

1. Switch of MS1002
2. Press button "Start" and "Stop" at the 

same time and hold both

3. Switch MS1002 back on again and wait 

until the display will appear again

4. Release the buttons

Errorcodes

E-1 = Short-circuit
E-2 = The connection to the temperature sensor

has been cut, for example the plug
isn´t installed properly.

E-3 = Humidity sensor has triggered
E-6 = Emergency program or after a blackout
E-7 = Short-circuit in the magnetic valve(s)

Remedy the error and press the "Start"
button before restarting, to delete the
error-message.

If the water is colder than 5°C the temperature
sensor has to be deactivated, or the error code
“E" will appear. For that switch off the MS1002,
press and hold the "Programm 2" key, and
switch the MS1002 back on. Release the button
not until the temperature is shown in the display.
After 60 seconds the setting is saved. Press,
while a programmis running, the button "Pro-
gramm2" to switch the temperature sensor off.
An "A" will appear in the lower half of the
display, which means that the temperature sen-
sor is switched off. The temperature sensor can
even be activated by doing that steps again.

Only the cold
water valve is opened

Complete display
is flashing

Complete display
is flashing

flashing

Summary of Contents for MS 1002

Page 1: ...MS 1002 Washing machine control gear User Manual...

Page 2: ...1 Important notes 4 2 Assembly and connection 4 3 Explanations 5 4 Display 6 5 Shipment MS1002 7 6 Assembly MS 1002 7 7 Initiation MS1002 8 8 Urgent notes for programming MS1002 8 9 Technical data 10...

Page 3: ...purchuase the Eckfix piece by us 2 Assembly and connection 1 Pull the plug of your washing machine 2 Unscrew the water hose of the washing machine at the water tap and even at the was hing machine 3 R...

Page 4: ...02 3 Explanations Display Enter keys On off switch Power cord 230 V Connection cold water valve blue Connection hot water valve red Connection feeler gauge at the mixing chamber Connection humidity se...

Page 5: ...ng program Short time for soaking Long time for soaking Starting later C Programm1 active Programm2 active Programm3 active Display for hot water magnetic valve Display for cold water magnetic valve D...

Page 6: ...nery and concrete When assembling at cavity walls for example plasterboard please use special dowels for cavity walls 3 Turn the bolts in until a gap of 3 4 mm bet ween wall and bolt headinside is rea...

Page 7: ...e switching the MS1002 off at the next start the error code E 6 will appear but you can delete this error by pres sing the Stop button 8 Urgent notes for programming MS1002 1 If the display is flashin...

Page 8: ...like the MS1002 weren t installed In this program the cold water valve is open and the power is always on To activate the emergency program just press the buttons Programm 1 Programm 2 and Programm3...

Page 9: ...eaking capacity 16 A Measures 180 mm x 140 mm x 58 mm weight 1 8 kg Magnetic valve 24 V AC 5 W thread Technical claim There must exist an automatic circuit breaker 16 A All changes serve the technical...

Page 10: ...MS 1002 11 MS 1002 Drilling jig...

Page 11: ...MS 1002 PH NIX SonnenW rme AG Ostendstra e 1 12459 Berlin Fax 030 53 000 717 info sonnenwaermeag de www sonnenwaermeag de Last update Oct 2007...

Reviews: