background image

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not   into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories 

 by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to 

  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’

 

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING: 

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the 

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Summary of Contents for STUDIO WIZARD

Page 1: ...STUDIO WIZARD Studio Monitor Controller...

Page 2: ...hting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug...

Page 3: ...hout prior notice V1 4 FEB 05 2008 Studio Monitor Controller INTRODUCTION 4 FEATURES 4 QUICK SETUP 5 Initial Setup 5 Level Setting 5 Signal Routing 5 MAIN UNIT 6 Front Panel 6 Rear Panel 7 REMOTE UNIT...

Page 4: ...be something you missed the first time around FEATURES Digital convenient routine volume control for precise level adjustments Switch amongst 3 sets of studio monitors Built in Talkback microphone for...

Page 5: ...signal routing if a prob lem occurs 4 Adjust the trim control of the correspond ing input on the front of the Studio Wizard s main unit so that the signal level sits around or slightly above the 0 ma...

Page 6: ...e activated when using condenser microphones 4 Stereo 4 Inputs RCA These RCA inputs accept unbalanced line level signals from CD players tape decks and other consumer audio devices 5 Internal and Exte...

Page 7: ...sive speakers You can use the speaker trim controls on the front panel to adjust the output level 16 Record Out 1 and 2 These stereo balanced 1 4 TRS and unbal anced RCA outputs provide line level sig...

Page 8: ...f your way users are free to move this small unit around as they see fit You can route your input signals to any number of possible outputs record studio etc as well as to speakers for monitoring with...

Page 9: ...ut Studio Select Section 30 Rec 1 and Rec 2 Buttons Press either of these buttons to select the inputs you wish to send to the Record 1 or 2 outputs on the main unit Hold either of these buttons down...

Page 10: ...des the se lected signal whether it be the speaker output only or all outputs simultaneously 41 Dim Level This knob adjusts the amount of attenuation ap plied when the Dim button is pushed 42 Dim Butt...

Page 11: ...n the Speaker Select zone 53 Digital LED Display This LED display provides a precise numeric readout for all level control changes The default display is the monitor level control When any of the Stud...

Page 12: ...al ensure they are turned on and up Are all volume and trim controls turned to an acceptable level Make sure your audio inputs and audio out puts are correctly selected Incorrect rout ing may be of co...

Page 13: ...CATIONS MICROPHONE TURNTABLE HEADPHONE COMPUTER SOUNDCARD MIXER HELIX BOARD 24 FIREWIRE STUDIO WIZARD REMOTE UNIT SUBWOOFER ACTIVE SPEAKERS PHONIC P8A ACTIVE MONITORS TAPE RECORDER SPEAKER AMPLIFIER D...

Page 14: ...1K 48K 96K 192K Mono Types XLR transformer balanced Audio Outputs Monitor out Type 1 4 TRS Balanced Nominal Line level setting 4dBu Trim Range to 18dB variable Output level maximum 18dB Dim switch Att...

Page 15: ...y 72dB Mic Preamp Gain control range 0 50dB Internal Microphone Type Electric Condenser Sensitivity 42dB Gain range 15 55dB Input Meters Type 20 segment LED Range 48dB to 15dB Accuracy Better than 25d...

Page 16: ...16 STUDIO WIZARD DIMENSIONS 482 19 195 7 7 44 1 7 All measurements are shown in mm inches...

Page 17: ...R r e l l o r t n o C o r c i M A H A M A Y E L B A C T E N R E H T E 2 D T S L R R R 3 N O M L 2 L A T I G I D L R 3 g o l a n A L 2 P H L N I A G 2 N O M L 1 D T S L R 2 C E R L N I A G N I A G 1 g...

Page 18: ......