background image

PCX4000

8

English     

SPECIFICATIONS

Audio Inputs

Connectors 

XLR

Type 

Electronically servo-balanced, HF filtered

Input Impedance 

Balanced >50 kohm, unbalance >25 kohm

Max. Input Level 

+22 dBu typical, balanced or unbalanced

CMRR 

>40dB, typical >55dB at 1 kHz

Audio Outputs

Connectors 

XLR

Type 

Electronically servo-balanced, HF filtered

Output Impedance 

Balanced 60 ohm, unbalance 30 ohm

Max. Output Level 

+20 dBu, balanced or unbalanced

Performance

Bandwidth

 20 Hz to 20 kHz, +0/-0.5 dB

Frequency Response 

<5 Hz to >60 kHz, +0/-3 dB

Signal to Noise Ratio 

Ref.: +4 dBu, 20 Hz to 20 kHz, unweighted

Stereo-Mode: 

Mono-Mode:

Low Output 

>94 dB 

>94 dB

Mid Output 

>94 dB

High Output 

>91 dB 

>89dB

Dynamic Range 

>106 dB, unweighted

THD & Noise 

<0.04%; <0.5% (limiter on)

Interchannel Crosstalk 

High to Low: <93 dB

High to Mid: <95 dB

Mid to Low: <96 dB

Interchannel 

Crosstalk High to Low: <93 dB

High to Mid: <95 dB

Mid to Low: <96 dB

High to High-Mid: <95 dB

High-Mid to Low-Mid: <95 dB

Low-Mid to Low: <92 dB

Crossover

Filter-Type 

Linkwitz-Riley, 24 dB/octave, state-variable

Mono Mode Frequencies 

x1 

x10

Low/High 

440 Hz to 9.3 kHz

Low/Mid/Mid/High 

440 Hz to 9.3 kHz

Stereo Mode Frequencies 

x1 

x10

Low/High 

44 to 930 Hz 

440 Hz to 9.3 kHz

Low/Mid

44 to 930 Hz 

440 Hz to 9.3 kHz

Mid/High 

440 Hz to 9.3 kHz

Summary of Contents for PCX 4000

Page 1: ...PCX 4000 User s Manual Manual del Usuario...

Page 2: ...ENGLISH I ESPA OL II V1 1 06 01 2012 High Precision Stereo 2 3 Way Mono 4 Way Crossover Crossover de Alta Precisi n Est reo 2 3 V as Mono 4 V as PCX 4000 English Espa ol...

Page 3: ...l 1 Rear Pane 2 3 Way Stereo Operation 3 Front Panel 3 Rear Panel 4 4 Way Mono Operation 5 Front Panel 5 Rear Panel 6 APPLICATION 6 SPECIFICATIONS 8 APPENDIX DIMENSIONS 1 BLOCK DIAGRAM 2 CONTENTS USER...

Page 4: ...ing lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord o...

Page 5: ...red output device to the PCX4000 s input connector Commonly this would be a mixer s auxiliary or main output 3 Connect all of your required input devices to the device s output connectors Commonly thi...

Page 6: ...se Holder This connector is used to supply power to the PCX4000 through theAC cable provided along with this unit The fuse holder located below this connector is used to house the connector s fuse If...

Page 7: ...s the level of the low band output between 6 and 6 dB 7 Low Phase Invert Control This button reverses the phasing of the low band output making the signal appropriate for out of phase or incorrectly w...

Page 8: ...his is particularly helpful when including additional subwoofers to your system 22 Low Output Connector This connector will output the low band signal 23 Crossover Frequency Button Pushing this button...

Page 9: ...Low Mid Output Control This controls the level of the low mid band output between 6 and 6 dB 10 Low Mid Phase Invert Button This button reverses the phasing of the low mid band output making the signa...

Page 10: ...vel can be cut and boost by up to 6 dB Provided the output level of your mixer is set to an acceptable degree setting all input controls to 0 dB should be perfectly acceptable In the event that the de...

Page 11: ...analyzer ready 3 Adjust the bands above and below your crossover frequency so that each of them produces a 0 dB reading at the crossover frequency as read by your analyzer Mute all bands other than th...

Page 12: ...o Noise Ratio Ref 4 dBu 20 Hz to 20 kHz unweighted Stereo Mode Mono Mode Low Output 94 dB 94 dB Mid Output 94 dB High Output 91 dB 89dB Dynamic Range 106 dB unweighted THD Noise 0 04 0 5 limiter on In...

Page 13: ...nada 120V 60 Hz Europe U K Australia 230V 50 Hz Japan 100V 50 60 Hz Power Consumption 20 W Fuses 100 120 V T630 mA H 200 240V T 315 mA H Mains Connection Standard IEC receptacle Dimensions 483 x 44 x...

Page 14: ...f the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorization In order to keep this warranty in e...

Page 15: ...o aviso INTRODUCTION 1 CARACTER STICAS 1 CONFIGURACI N R PIDA 1 OPERANDO PCX4000 1 Operaci n Est reo de 2 Caminos 1 Panel Frontal 1 Panel de Dorso 2 Operaci n Mono de 3 Caminos 3 Panel Frontal 3 Panel...

Page 16: ...PCX4000 12 English Espa ol...

Page 17: ...idad est apagada Preferentemente remueva el cable de corriente alterna 2 Conecte su dispositivo de salida requerido a conector de entrada de PCX4000 En general sto ser a un auxiliar de mezcladora o sa...

Page 18: ...Dorso 14 Conector de Corriente Alterna y Portafusible Este conector es usado para suministrar energ a a PCX4000 por el cable de cor r iente al terna proporcionado con esta unidad El portafusible loca...

Page 19: ...n fase 6 Control de Salida Baja ste controla el nivel de salida de baja banda entre 6 y 6 dB 7 Control de Invertir de Fase Baja Este bot n invierte las fases de salida de banda baja haciendo la se al...

Page 20: ...vo sobre los altavoces u otro equipo 21 Bot n de Suma Baja En modo est reo pulsando este bot n combinar los dos canales de frecuencia baja y enviarlos por el canal 1 salida de frecuencia baja solo Est...

Page 21: ...er la se al de banda baja 9 Control de Salida Media Baja ste controla el nivel de salida de banda media baja entre 6 y 6 dB 10 Bot n de Invertir de Fase Media Baja Este bot n invierte las fases de sal...

Page 22: ...condici n de que el nivel de salida de su mezcladora sea seteado a un grado aceptable configurando todos los controles de entrada a 0 dB deber a ser absolutamente aceptable En el caso de que el dispos...

Page 23: ...l ruido rosa a trav s de su sistema y tenga su analizador a mano listo 3 Enmudece todas las bandas distintas de las dos que rodea la frecuencia de crossover Si las dos bandas juntas producen una lectu...

Page 24: ...3 dB ndice de Se al a Ruido Ref 4 dBu 20 Hz a 20 kHz inponderado Modo Est reo Modo Mono Salida Baja 94 dB 94 dB Salida Media 94 dB Salida Alta 91 dB 89dB Rango Din mico 106 dB inponderado THD Ruido 0...

Page 25: ...A Canad 120V 60 Hz Europa Reino Unido Australia 230V 50 Hz Jap n 100V 50 60 Hz Consumo de Energ a 20 W Fusible 100 120 V T630 mA H 200 240V T 315 mA H Conexiones Principales Est ndar IEC recept culo D...

Page 26: ...de la fecha de compra Va a necesitar este comprobante para cualquier servicio de garant a No se aceptar n reparaciones o devoluciones sin un n mero RMA apropiado return merchandise autorization En ord...

Page 27: ...PCX4000 Appendix Ap ndice measurements are shown in mm inches DIMENSIONS DIMENSIONES Todas las medidas est n mostradas en mm pulgadas 482 6 19 3 7 1 4 4 2 1 8 3 6 0 2...

Page 28: ...UTE MUTE INPUT THRESOLD LIMITER XOVER FREQ 25Hz HPF HF INPUT 2 LOW CUT NOT USED LOW LOW CUT GAIN 24dB Oct Linkwitz Riley Filter MUTE GAIN NOT USED HIGH HIGH MID MID MONE MONO CD HORN STEREO 24dB Oct L...