background image

4

AM821X / AM1221X / AM1621X / AM2421X

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not   into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories 

 by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to 

  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’

 

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING: 

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the 

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

English     

Summary of Contents for AM 1221X

Page 1: ...AM2421X AM 821X AM 1221X AM 1621X AM 2421X User s Manual Manual del Usuario...

Page 2: ...MIXING CONSOLE CONSOLA DE MEZCLA English Espa ol ENGLISH I ESPA OL II V2 0 05 18 2012 AM 821X AM 1221X AM 1621X AM 2421X...

Page 3: ...IXING PANEL 3 CONTROLS AND SETTINGS 3 REAR PANEL 3 CHANNEL CONTROLS 4 DIGITAL EFFECT ENGINE 5 TAPE IN SECTION 6 MASTER CONTROL SECTION 6 SPECIFICATIONS 8 APPENDIX DIGITAL EFFECT TABLE 1 APPLICATIONS 2...

Page 4: ...s during lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply c...

Page 5: ...0VAC 50 60Hz Optional rack mounting kit for AM821X only model name ER8IM 32 40 bit digital multi effect processor with 16 programs with parameter control and tap delay BASIC SETUP GETTING STARTED 1 En...

Page 6: ...inputs and 1 4 TS phone jacks They can be used in con junction with various stereo devices such as synthesizers and keyboards Also by connecting a mono signal to the left phone jack the mixer automati...

Page 7: ...12 Volt 7 Watt gooseneck lamp allowing better visability in areas with poor light 13 Power Connector This is for the addition of an AC power cable allowing power to be supplied to the mixer Please us...

Page 8: ...channel and bring more warmth and punch to drums and bass gui tars 24 AUX Controls These two AUX controls alters the signal level that is be ing sent to the auxiliary 1 and 2 mixing buses the signal...

Page 9: ...ushing this but ton twice will allow the processor to calculate the time between the two pushes and use this as the tap delay time If the button is pushed multiple times the proces sor will calculate...

Page 10: ...the Control Room Phones mixing bus 47 Phantom Power Button and Indicator When this button is pushed in 48V of Phan tom Power is activated for all microphone in puts allowing condenser microphones wel...

Page 11: ...indica tor illuminates about 1 5 dB before the signal is dynami cally clipped To make the maximum use of audio set the various level controls so that it sits steadily around 0 dB to make full use of a...

Page 12: ...Solo AFL 4 4 4 4 Stereo Aux Returns 2 2 2 2 Effects Return to Monitor 3 3 3 3 Faders 60 mm Efx Rtn Aux 1 Aux 2 Mono Main L R Metering Number of Channels 2 2 2 2 Segments 12 12 12 12 Phantom Power Supp...

Page 13: ...1 1 K ohms 1 1 K ohms 1 1 K ohms 1 1 K ohms Equalization 3 band 15dB 3 band 15dB 3 band 15dB 3 band 15dB Low EQ 80Hz 80Hz 80Hz 80Hz Mid EQ mono channel 100 8k Hz sweepable 100 8k Hz sweepable 100 8k H...

Page 14: ...e of the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorization In order to keep this warranty i...

Page 15: ...1 CARACTERIST CAS 1 CONFIGURACI N B SICA 1 INICIANDO 1 CONFIGURACI N DE CANAL 1 HACIENDO CONEXIONES 2 PANEL DE CONEXI N 2 PANEL DE DORSO 3 PANEL PRINCIPAL DE MEZCLA 3 CONTROLES Y AJUSTES 3 PANEL DE DO...

Page 16: ...12 AM821X AM1221X AM1621X AM2421X English Espa ol...

Page 17: ...solamente modelo ER81M 32 40 bit preocesador digital de multi efectos 16 programas con control de par metro y tap retardo CONFIGURACI N B SICA INICIANDO 1 Aseg rese de que toda la energ a est apagada...

Page 18: ...n conjunto con varios dispositivos est reo como sintetizadores y teclados Tambi n conectando una se al mono al jack de aud fono izquierdo la mezcladora copiara autom ticamente la se al sobre el canal...

Page 19: ...s para agregar un cable de energ a AC alimentando as a la mezcladora Por favor utilice el cable incluido con esta mezcladora nicamente El portafusible localizado debajo de conector de energ a AC es po...

Page 20: ...eran el nivel de se al que est siendo enviada a los buses de mezcla auxiliar 1 y 2 cuya se al es adecuada para conectar monitores de escenario permitiendo a los artistas escuchar la m sica que se est...

Page 21: ...de tap delay es seleccionado pulsando este bot n dos veces permitir al procesador calcular el tiempo entre las dos pulsadas y lo toma como el tiempo de tap delay Si el bot n es pulsado varias veces e...

Page 22: ...ios enviar la se al post fader al bus de mezcla de Control Room Phones 47 Bot n Fuente Fantasma e Indicador Cuando se presiona este bot n se activar Fuente Fantasma de 48V para todas las entradas de m...

Page 23: ...balanceado y el indicador de pico se ilumina alrededor de 1 5 dB antes de que la se al sea din micamente recortada Para el uso m ximo de audio setee varios controles de nivel para que se tenga una le...

Page 24: ...ster Env os AUX Masters 4 4 4 4 Solo de Env o AUX Master AFL 4 4 4 4 Retornos AUX Est reo 2 2 2 2 Retorno de Efectos a Monitor 3 3 3 3 Faders 60mm Efx Rtn Aux 1 Aux 2 Mono Main L R Medici n N mero de...

Page 25: ...s 10 K ohms 10 K ohms Todas las Otras Salidas 100 ohms 100 ohms 100 ohms 100 ohms Salidas 2T RCA 1 1 K ohms 1 1 K ohms 1 1 K ohms 1 1 K ohms Ecualizaci n 3 bandas 15dB 3 bandas 15dB 3 bandas 15dB 3 ba...

Page 26: ...o evidencia de la fecha de compra Va a necesitar este comprobante para cualquier servicio de garant a No se aceptar n reparaciones o devoluciones sin un n mero RMA apropiado return merchandise autoriz...

Page 27: ...0 sec 5 Arena Reverb Time 0 3 10 sec 6 Spring Reverb Time 0 3 10 sec 7 Opera Reverb Time 0 3 10 sec 8 Rev Vocal Reverb Time 0 3 10 sec 9 Slap Delay Delay Time 0 800 ms 10 Echo Delay Time 0 800 ms 11 M...

Page 28: ...FICADOR AMPLIFIER MONITORES DE ESCENARIO STAGE MONITORS AMPLIFICADOR INTERRUPTOR DE PEDAL GRABADORA DE 2 PISTAS 2 TRACK RECORDER 2 AUD FONOS MICROPHONES MICR FONOS BASS GUITAR GUITARRA BASS EFECTOS DE...

Page 29: ...CR FONOS ACTIVE MONITORS CASSETTE RECORDER GRABADORA DE CASSETTE MONITORES ACTIVOS SPEAKERS ALTAVOCES ALTAVOCES ACTIVOS FOH CD AMPLIFIER 70V AMPLIFICADOR ALTAVOCES 70 V DISTRIBUIDOS POR EDIFICIO DRUM...

Page 30: ...AM1621X AM2421X X mm inches 440 17 3 572 22 5 704 27 7 968 38 1 Y mm inches 510 20 642 25 3 774 30 5 1038 40 9 473 22 17 2 Y X 106 50 4 2 88 50 3 5 49 94 1 97 measurements are shown in mm inches Todas...

Page 31: ...EFT PFL R LEFT AUX 1 AUX 2 CUE_C CUE_C CUE_C AFL L AFL L AFL R CUE_A CUE_A AFL L AFL R AFL L CUE_A EFFECT_IN LMID LMID MINI STEREO 12K 100 8K 80 3 BAND TONE 12V LAMP INS PEAK AUX 2 DSP EFX2 PROGRAM LE...

Page 32: ......