Leaving a MultiTalker Network 

 

The MultiTalker Network cannot exist without the presence of your initiating inspiro in the 
network. If you decide to end the MultiTalker Network, the entire network will cease and all 
of the inspiro and DynaMic transmitters will activate an alarm. 
 
If you are using an inspiro that just joined a network, you can always leave the network by 
selecting Stop MultiTalker Network.  
Your inspiro will then be set to single teaching mode, but all of the other inspiro 
transmitters in the MultiTalker Network will remain in MultiTalker Network mode. 
 
If you are switching off one of the DynaMic, it will be deleted from your participants list. 
The MultiTalker Network could continue with all other DynaMic and inspiro transmitters.  
 
Should you unintentionally be outside the distance range of the MultiTalker Network, you 
will be alerted by an alarm. You can then choose to either return to the operating range of 
a maximum  8m / 25 feet from the initiating inspiro, or to leave the network. 
 

Practical tips 

 
 

  The MultiTalker network setting is stored in the inspiro transmitters. If the inspiro and 

DynaMic transmitters have been switched off in MultiTalker Network mode, e.g. before 
lunch, when decided to then switched back on again after lunch, the MultiTalker 
Network mode can be selected by simply pressing a key in the inspiro. In this case, 
there is no need to re-initiate the network. 

However, start the inspiro first

. All the 

DynaMic transmitters will join the network in the pairing window of 8 sec after the 
initiator inspiro was switched on. 
 

  If you have set up a MultiTalker Network with for instance two inspiro transmitters and 

then a third person needs to subsequently join the network with inspiro or DynaMic, it is 
necessary to set up a new network (to initiate a new MultiTalker Network).  

 

  inspiro and Dynamic transmitters joining a network automatically use the FM channel of 

the initiating inspiro in the MultiTalker Network. 
 

  If an inspiro reverts to single teaching mode, it automatically applies the FM channel 

used previously. 
 

  If the initiating inspiro alters the FM channel in MultiTalker Network mode for any 

reason, the new channel will automatically be sent to the other inspiro and DynaMic 
transmitters in the network and then activated. 

 
 
 

Summary of Contents for DynaMic

Page 1: ...1 User Guide DynaMic ...

Page 2: ...arm indication Switch on DynaMic Using DynaMic User cases Pass around microphone Talking Colored rings DynaMic Data Logging Programming The MultiTalker Network Initiating a MultiTalker Network How to use a MultiTalker Network Leaving a MultiTalker Network Practical tips Troubleshooting Important notices Service and warranty Declaration of conformity ...

Page 3: ...any years DynaMic is a quality product developed by Phonak Phonak is the world leader in FM technology innovation and reliability based in Switzerland Further resources To find out more about DynaMic as well as about Phonak FM in general we recommend visiting the following websites www eSchoolDesk com This is a special website specifically dedicated to providing support to teachers but also to par...

Page 4: ...livered with Desk stand Clamp 3 8 5 8 Colored rings All the accessories can also be ordered separately 1 DynaMic microphone 2 Desk stand base and legg with clamp 3 Colored rings red yellow green 4 Charging unit 5 Replacement microphone head ...

Page 5: ...enna length 15 cm Weight 110g Operating time and charging Operating time if the battery is fully charged up to 10 hours Charging time for an 80 charge approx 1 hour Charging time for an 100 charge approx 2 hours Operating range FM transmission Operating range to initiator inspiro inside 8 m outside 15 m ...

Page 6: ...e not affected by this operation Use a pen to press the button 3 Built in vibrator The vibration alarm provides information on the status of the battery and operation 4 FM Antenna It emits FM to the receivers in the hearing instruments 5 Mini USB interface Interface for charging and programming 6 The LED indicates the following functionalities battery status charging error states 1 2 3 4 5 6 ...

Page 7: ... takes one hour for an 80 charge and two hours for a 100 charge Use only the original Phonak charging unit for inspiro DynaMic To simultaneously charge your inspiro and DynaMic we recommend the twin charger Select an easily accessible socket outlet and plug the charging unit into the socket outlet Connect the Mini USB plug from the charging unit to the DynaMic During charging the LED flashes two s...

Page 8: ...time DynaMic switches off automatically after flashing 10 flashes Vibration alarm indication The transmitter provides a vibration alarm if The battery is low The device is out the range of the initiator of the MultiTalker Network DynaMic is muted for more than 15 minutes There is no FM transmission DynaMic is not paired The distance in the MultiTalker Network is higher than 8m System problem which...

Page 9: ...iro push the slider to the left until the green mark appears and the LCD starts up Set up the MultiTalker Network Initiate your Multitalker Network by pressing OK Start your DynaMic by pushing the slider from Off to On ...

Page 10: ...ter After switching On the microphone the LED turns off to save power On the list of participants the microphone can be recognized As described earlier in the chapter Switching on inspiro pg 25 it is recommended to activate the key pad lock whenever possible Mute If the DynaMic is On it is possible to mute the microphone Switch the slider from On to Mute If DynaMic is not paired in the MultiTalker...

Page 11: ...ild to the next Talking Inspiro Follow all the steps described in the chapter Talking under inspiro chapter pg 28 DynaMic Make sure DynaMic is recognized into the MultiTalker Network by the initiator inspiro You can check this on the inspiro s LCD is within the right distance in the MultiTalker Network is turned on is not in the muted mode Speak into the microphone at relatively close range When s...

Page 12: ... every 15 minutes The first log entry is stored after the transmitter has worked for 15 minutes A usage data log contains e g name timestamp MTN mode average noise level Dynamic can store up to 800 data log which covers approx 20 days of usage Programming Programming is optional the frequency is automatically selected by the initiating inspiro in the MultiTalker Network The following parameters co...

Page 13: ...ilable in the inspiro s Extended operating mode The Network operating range i e the distance between the initiating inspiro and each inspiro DynaMic joining the network is 8 m 25 feet If a user should unintentionally leave the network an alarm signal of the inspiro DynaMic alerts the user Diagram of the MultiTalker Network The initiating inspiro displays a list of the other transmitters in the Mul...

Page 14: ...ransmitters that have joined the network should now be displayed on the initiating inspiro If all of the transmitters are listed press the Continue soft key You have successfully created the network All inspiro and DynaMic transmitters are synchronized by the initiator inspiro Begin talking as usual How to use a MultiTalker Network The inspiro that has set up initiated the network has first priori...

Page 15: ...alker network setting is stored in the inspiro transmitters If the inspiro and DynaMic transmitters have been switched off in MultiTalker Network mode e g before lunch when decided to then switched back on again after lunch the MultiTalker Network mode can be selected by simply pressing a key in the inspiro In this case there is no need to re initiate the network However start the inspiro first Al...

Page 16: ...activate the microphone Also check whether the hearing devices are turned on and set to the right programme Activate the Monitoring function on the inspiro to check the receivers Insufficient operating range Microphone cable has not been unwound Unwind the microphone cable Radio interference External cause radio antenna or similar interfering devices nearby Change the FM channel Use the ChannelFin...

Page 17: ...vice has not been set to the right programme Often drops Check the DynaMic is not muted Also check whether the hearing devices are turned on and set to the right program The acoustic part is deteched Insufficient operating range DynaMic s antenna or head are partially covered The colored rings are covering the acoustic part Leave free the DynaMic s antenna and head Placed only 2 colored rings to p...

Page 18: ... except in the case of transmitters in a MultiTalker Network Please note that radio signals might also be picked up and overheard by other receivers Before using the inspiro in another country contact your hearing care professional to make sure the use of your radio channels is permitted in that country Do not use water or other liquids to clean the inspiro and DynaMic Use only original Phonak acc...

Page 19: ...ose address can be taken from the list of Phonak distributors worldwide This device complies with part 15 and part 95 of the FCC rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 These devices do not cause harmful interference and 2 must accept any interference received including interference that may cause undesired operation These transmitters are a...

Page 20: ...s made to this equipment not expressly approved by Phonak may void the user s authority to operate the equipment Your hearing care professional www phonak com 029 3042 V1 002 2009 01 Printed in Switzerland Phonak AG All rights reserved ...

Reviews: