 (Hotplate) Magnetic Stirrer

 

Preface 

Welcome  to  the  RSM-10  (Hotplate)  Magnetic  Stirrer”. 

Users  should  read  this  Manual  carefully,  follow  the 

instructions  and  procedures,  and  be  aware  of  all  the 

cautions when using this instrument.   

Service 

When  help  needed,  you  can  always  contact  the  Service 

Department  of  manufacturer  for  technical  support  in  the 

following ways: 

 

Phoenix Instruments GmbH 

Heinkelstr. 10 

308927 Garbsen/Germany 

Tel: +49-5131-9081890 

Fax: +49-5131-9081839 

E-mail: [email protected] 

Http://www.phoenix-instrument.de

 

 

 

 

Please provide the customer care representative with the 

following information

 

• Serial number

on the rear panel

 

• 

Certification

 

• Description of problem (i.e., hardware or software) 
• Methods and procedures adopted to resolve the problems 
• Your contact information 

Warranty 

This  instrument  is  warranted  to  be  free  from  defects  in 

materials  and  workmanship  under  normal  use  and  service, 

for  a  period  of  24  months  from  the  date  of  invoice.  The 

warranty is extended only to the original purchaser. It shall 

not apply to any product or parts which have been damaged 

on  account  of  improper  installation,  improper  connections, 

misuse, accident or abnormal conditions of operation. 

For  claims  under  the  warranty  please  contact  your  local 

supplier.  You  may  also  send  the  instrument  directly  to 

manufacturer,  enclosing  the  invoice  copy  and  by  giving 

reasons for the claim.

Summary of Contents for RSM-10HS/HP

Page 1: ...ser Manual RSM 10HS HP LED Digital Hotplate Magnetic Stirrer RSM 10P LED Digital Magnetic Stirrer Please read the User Manual carefully before use and follow all operating and safety instructions www phoenix instrument de 12300174 ...

Page 2: ...l 4 4 1 Control elements 4 4 2 Display 7 5 Trial Run 8 6 Function Heating Digital hotplate model 8 6 1 Working with external temperature sensor 9 6 2 Residual heat warning HOT 9 7 Stirring 10 8 Faults 10 9 Maintenance and Cleaning 11 10 Associated Standards and Regulations 11 11 Specifications 12 12 Ordering InformationFehler Textmarke nicht definiert ...

Page 3: ...e following information Serial number on the rear panel Certification Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only t...

Page 4: ...res with hazardous substances or under water Gradually increase the speed reduce the speed if Stirring bar breaks away due to high speed The instrument is not running smoothly or container moves on the base plate Temperature must always be set at least 50 lower than the fire point of the media used Be aware of hazards due to Flammable materials or media with a low boiling temperature Overfilling o...

Page 5: ...ot touch the hotplate Do not cover the device The instrument may only be opened by experts Keep away from high magnetic field 2 Proper Use The instrument is designed for mixing and or heating liquids in schools laboratories or factories Observe the minimum distances between the devices between the device and the wall and above the assembly min 100 mm 100mm Figure 1 This device is not suitable for ...

Page 6: ...er for technical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The package includes the following items Items Qty Main unit 1 Power cable 1 Stirrer bar 1 User Manual 1 Table 1 4 Control 4 1 Control elements Speed Control Knob LED Display Temperature Control Knob Hotplate model Probe Hotplate model Figure 2 Digital hotplate...

Page 7: ...5 BlueSpin Hotplate Magnetic Stirrer Speed Control Knob LED Display Figure 3 Digital model Speed Control Knob Figure 4 Classic model Figure 5 ...

Page 8: ...l working state and all settings Probe When the external temperature sensor PT1000 is plugged in probe icon is lit Power Switch Switch ON or OFF the instrument Digital model Temperature Control Knob Stir Set the rotary speed The function Stirring is switched ON or OFF via push ON OFF knob LED Display LED displays the real working state and all settings Power Switch Switch ON or OFF the instrument ...

Page 9: ... temperature is still above 50 C LED displays Hot otherwise LED displays OFF Speed display area When stirring function was switched ON LED displays the speed setting value and flashes The setting value does not flash until real speed reaches the set point Table 3 Speed display area Figure 7 Digital model Characters Descriptions Speed display area When stirring function was switched ON LED displays...

Page 10: ...ating Digital hotplate model The device is controlled by digital temperature control technology which has two separate safe circuits The hotplate is kept at a constant temperature by a digital control circuit The hotplate temperature can also be monitored from a separate adjustable safe circuit The two temperature sensors internal for temperature control are built into the hotplate The single exte...

Page 11: ...conditions Please operate follow the instructions below Switch OFF the instrument Ensure the external temperature sensor is inserted in the media heated Switch ON the instrument and run heating function If the heating function does not work please contact manufacturer supplier for technical support 6 2 Residual heat warning HOT In order to prevent the risk of burns from a hotplate digital hotplate...

Page 12: ...ther the power line is unplugged Check whether the fuse is broken or loose Fault in power on self test Switch OFF the unit then switch ON and reset the instruments to factory default setting Stir speed cannot reach set point Excessive medium viscosity may cause abnormal speed reduction of the motor Unit cannot be powered off when switched off Check if the residual heat warning function is still ON...

Page 13: ...s method will not harm the instrument Wear the proper protective gloves during cleaning of the instrument Note Electronic device can not clean with cleanser If you require maintenance service must be cleaned the instrument in advance to avoid pollution of hazardous substances and to send back into original packing If the instrument will not use for a long time please switch off and place in a dry ...

Page 14: ... if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 11 Specifications Items Specifications Digital model Classic model Voltage VAC 100 120 200 240 100 ...

Page 15: ...play accuracy C 1 The safe temperature of hotplate 320 Temperature sensor in medium PT1000 Control accuracy of heating temperature with temperature sensor 0 5 Residual heat warning 50 Dimensions mm 220 160 95 Items Specifications Digital model Classic model 220 160 75 Weight kg 1 4 0 7 0 7 Permitted ambient temperature C 5 40 Permitted relative humidity 80 Protection class acc to DIN 60529 IP21 IP...

Reviews: