background image

BLU-14

RED-13

COMPRESSOR

BLOWER MOTOR

LEVEL 

SWITCH

CONTROL 

BOARD

THERMISTOR

CONDENSATE PUMP

WHT

-10

GRN

BLK

WHT-2

YEL-9

YEL-8

RUN 

CAP

ACIT

OR

RUN 

CAP

ACIT

OR

BLK-3

YEL-7

E1

E3

E2

E5

E4

BLK-5

BRN-6

BLK-12

BLU-18

BLK-4

WHT

S

R

C

4026354 C

Figure 11: Wiring diagram

7

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

6 Options & Accessories

4024750  

Inlet Flex Duct 12” x 25”  

 

Metallize Polyester

4024935  

Lay-Flat Duct 10” Round x 250’ Roll

To order, contact Therma-Stor LLC at 1-800-533-7533.

7 Wiring Diagram

Summary of Contents for R250

Page 1: ... Filter A 12 x12 x1 MERV 11 filter is standard Stacking Nesting Reduces space for ease of stacking and storage Patented ByPass Technology Increased performance over a wide temperature range Specifications subject to change without notice TS 889 08 15 4201 Lien Rd Madison WI 53704 Phoenix R250 Part No 4034460 Patent 7 246 503 D570 988 8 069 681 The Phoenix R250 has been redesigned from the inside o...

Page 2: ...at Warranty Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of sealed refrigeration system parts Dimensions Unit Shipping Width 20 21 Height 33 5 35 25 Depth 20 21 Weight 109 lbs 125 lbs Patent 7 246 503 D570 988 8 069 681 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a large water tight container and turn on To decrease drying times make sure al...

Page 3: ...ng the spiral wire under the four tabs Tape the duct to the top cover for a complete seal 3 6 Defrost Cycle If the low side refrigerant temperature drops below the defrost set point due to excessive frost formation on the evaporator coil the thermistor activates the solid state control and the defrost light The control cycles the compressor off and on by the thermistor temperature measurement The ...

Page 4: ...uld become clogged and require disassembly to clean 4 2 Storage There are two issues to consider when the Phoenix R250 is stored between uses and both pertain to the water trapped in the unit damage caused by freezing or biological growth The effect of the trapped water can be greatly reduced if precautions are taken to remove as much as possible before storage 1 Use the pump PURGE button to reduc...

Page 5: ...ontinuously but compressor only runs sporadically 1 Unit is in defrost cycle DEFROST light on 2 Defrost thermistor defective or loose 3 Loose connection in compressor circuit 4 Defective compressor overload 5 Defective compressor 6 Defective relay 7 Upper housing is not sealed to lower housing No dehumidification air mover runs but compressor does not 1 Bad connection in compressor circuit 2 Safet...

Page 6: ... Reassemble thermistor and dehumidifier using the above procedure in reverse Figure 10 Picture of the float safety switch 5 5 Condensate Pump The internal condensate pump removes water that collects in the reservoir To replace the condensate pump 1 Unplug the unit 2 Remove the front housing 3 Unplug the pump wires from the wire harness 4 Remove the condensate hose and the one screw attaching the p...

Page 7: ...BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 11 Wiring diagram 7 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 6 Options Accessories 4024750 Inlet Flex Duct 12 x 25 Metallize Polyester 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 7 Wiring Diagram ...

Page 8: ...ord 1 4032315 14 Control Board 1 4026763 15 Capacitor Compressor 50 μF 1 4033032 06 16 Capacitor Impeller 15 μF 1 4033031 07 17 Thermistor 1 4031279 18 Handle lever 1 4026350 Description Qty Part No Compressor 1 4035407 Evaporator Coil 1 4033995 02 Condenser Coil 1 4033996 Condensate Pump 1 4034582 01 Float Safety Switch 1 4034374 Description Qty Part No Impeller Air Mover 1 4026657 Exhaust Grill ...

Page 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R250 Dehumidifier part is repaired...

Reviews: