Item  Description  

Qty  

Part No.

1   Filter, Cooling, 2 x 16 x 20  

1  

4021475

2   Cord  

1  

4026890

3   Front Panel Retaining Nut, 1/4-20   6  

4023362

4   Wheel, 8”  

2  

4025676

 

Wheel Hub Cap  

2  

4024816

 

Retaining Ring  

2  

4025454

 

Hub Cap Retaining Washer  

2  

4025295

5   Coupling Body, 1/4 Tube  

1  

4024910

6   Foot 

2  

4024073

7   Defrost Timer  

1  

4021823

8   Low Pressure Control  

1  

4029508

9   Filter/Drier  

1  

4029510

10   Compressor 

1  

4029190

 

Overload, Compressor  

1  

4029714  

 

Capillary Tubes  

3  

4030087

12   Defrost Thermostat  

1  

4025741

 

Defrost Control Mounting Clip 

4021648

13   Evaporator Coil  

1  

4033925-02

14   Accumulator  

1  

4022254

15  Condensate Pump  

1  

4034495 

16  10” Wire Duct Collar (Cooling)  

1  

4024078 

17   Top  

1  

4029267

18   Handle Assembly  

1  

4026094

19   Pump Purge Switch  

1  

4021796

20   Hour Meter  

1  

4028795

21   Power Switch  

1  

4021822

22   Skid Plate  

1  

4026839

23   Instruction Label  

1  

4026857

24   Handle Screw (M10-1.5 x 35)  

2  

1177792

 

Handle Nut (M10-1.5)  

2  

1223780

25  Thermostat 

4026885 

26  Filter, Exhaust, 1 x 12 x 20 

4026884

27  10” Duct Ring 

4022611

Items listed below are not shown

Drain Hose (.25 ID x 33’ long)  

1  

4024916

Front Panel Screw, 1/4-20 x 1/2  

1  

1096006

Condenser Coil  

1  

4028226

Motorized Impeller Fan  

2  

4025076

Relay, Compressor  

1  

1970010

Run Capacitor, Comp. 45 μF  

1  

4033032-05

Run Capacitor, Fan, 15 μF  

2  

4033031-07

14” Wire Duct Collar 

4024079

14” to 10” Duct Adapter 

4026845

8 Service Parts

Specifications subject to change without notice.

1

2

3

4

9

10

11

12

15

5

6

14

13

7

8

24

17

18

19

20

21

22

23

25

26

27

Summary of Contents for Phoenix Arctic Max

Page 1: ...rs When used in conjunction with the Phoenix Solution LGR performance amplifier the Phoenix Arctic Max provides a reliable cooling air stream to maximize overall performance The Phoenix Arctic Max fea...

Page 2: ...ns carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Arctic Max dehumidifier It is designed to be used INDOORS ONLY If us...

Page 3: ...ctic Max plugs into a common grounded outlet on a 15 Amp circuit It draws 11 8 Amps at 95 F 60 RH If used in a wet area a ground fault interrupter GFI is required If an extension cord is required it m...

Page 4: ...ly If the unit will not be exposed to freezing temperatures an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polye...

Page 5: ...perature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defrost timer incorrectly set for conditions...

Page 6: ...avity Drain Option If the condensate pump fails and cannot be replaced immediately the Phoenix Arctic Max can be used by draining by gravity 1 Unplug the unit and remove the front cover 2 Push the pla...

Page 7: ...r LLC PO BOX 8680 MADISON WI 53708 CAP YEL RED WHT WHT WHT BLU COMPRESSOR COMP BLK BLOWER CONTROL BLK BLK 5 3 2 MOTOR DEFROST 1 TIMER MOTOR SWITCH TIMER WHT VIO 1 DEFROST TIMER CONTROL THERMOSTAT BLK...

Page 8: ...Pump 1 4034495 16 10 Wire Duct Collar Cooling 1 4024078 17 Top 1 4029267 18 Handle Assembly 1 4026094 19 Pump Purge Switch 1 4021796 20 Hour Meter 1 4028795 21 Power Switch 1 4021822 22 Skid Plate 1 4...

Page 9: ...is warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident...