background image

1

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

Phoenix Arctic Max
PN 4030120

Owner’s Manual  —  Phoenix Arctic Max

Installation, Operation and Service Instructions

Read and Save These Instructions

The new Phoenix Arctic Max is the first portable air condi-
tioner designed specifically for the Restoration Industry. 
The Phoenix Arctic Max boasts one ton (12,000 BTUs) of 
cooling capacity operating in 95°F and 60% conditions while 
drawing under 12 amps. In a single pass, this provides a 
15 degree temperature drop on the 430 CFM evaporator 
(cooling) air stream and water removal equivalent to 100 
pints per day. 

The Phoenix Arctic Max gives the restoration contractor vital 
temperature control in the affected area to optimize drying 
efficiency or in unaffected areas to safe-guard occupant 
comfort. The Phoenix Arctic Max’s cooling power also 
makes it the ideal accessory to pre-treat air to improve the 

performance of desiccant or LGR dehumidifiers. When used 
in conjunction with the Phoenix Solution LGR performance 
amplifier, the Phoenix Arctic Max provides a reliable cooling 
air stream to maximize overall performance. The Phoenix 
Arctic Max features thermostatically controlled cooling to 
insure maintenance of desired conditions and prevent  
potential over-cooling.   

Set-up and operation is simple using the Phoenix window 
accessory kit, and a 15 amp outlet. The Phoenix Arctic Max 
also features filter efficiency options up to MERV-11, an 
internal condensate pump with 30 foot drain hose and 20 
foot power cord. The Phoenix Arctic Max promises years of 
service and our “proven” performance.

The Phoenix Arctic Max 
Portable Air Conditioner

• 1 Ton, 12,000 BTUs of Cooling*
• 100 Pints/Day of Water Removal*
• 11.8 Amps*
• Adjustable Thermostat
• Easy Set-up and Operation
• Cooling (Evaporator) Airflow 430 CFM
• Exhaust (Condenser) Airflow 430 CFM
• Multiple Ducting Options
• Multiple Filter Options
• 20 ft. Vertical Lift Condensate Pump
• 30 ft. Drain Hose
• 20 ft. Power Cord (grounded)
• Recessed Wheels
• Legendary Stainless Construction

*95ºF/60% RH

Specifications subject to change without notice.

TS-685

05/13

4201 Lien Rd • Madison, WI 53704

Summary of Contents for Phoenix Arctic Max

Page 1: ...rs When used in conjunction with the Phoenix Solution LGR performance amplifier the Phoenix Arctic Max provides a reliable cooling air stream to maximize overall performance The Phoenix Arctic Max fea...

Page 2: ...ns carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Arctic Max dehumidifier It is designed to be used INDOORS ONLY If us...

Page 3: ...ctic Max plugs into a common grounded outlet on a 15 Amp circuit It draws 11 8 Amps at 95 F 60 RH If used in a wet area a ground fault interrupter GFI is required If an extension cord is required it m...

Page 4: ...ly If the unit will not be exposed to freezing temperatures an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polye...

Page 5: ...perature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defrost timer incorrectly set for conditions...

Page 6: ...avity Drain Option If the condensate pump fails and cannot be replaced immediately the Phoenix Arctic Max can be used by draining by gravity 1 Unplug the unit and remove the front cover 2 Push the pla...

Page 7: ...r LLC PO BOX 8680 MADISON WI 53708 CAP YEL RED WHT WHT WHT BLU COMPRESSOR COMP BLK BLOWER CONTROL BLK BLK 5 3 2 MOTOR DEFROST 1 TIMER MOTOR SWITCH TIMER WHT VIO 1 DEFROST TIMER CONTROL THERMOSTAT BLK...

Page 8: ...Pump 1 4034495 16 10 Wire Duct Collar Cooling 1 4024078 17 Top 1 4029267 18 Handle Assembly 1 4026094 19 Pump Purge Switch 1 4021796 20 Hour Meter 1 4028795 21 Power Switch 1 4021822 22 Skid Plate 1 4...

Page 9: ...is warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident...

Reviews: