background image

 

 

N5488100F-1 

 

PHOENIX

7

 

INSTALLATION INSTRUCTIONS AND REPAIR PARTS LIST FOR

 

HIGH PRESSURE SODIUM INTEGRAL BALLAST FLOODLIGHTS

 

120 VOLTS, 50-150 WATTS

 

Models MSD 50HPS-120, MSD 70HPS-120, MSD 100HPS-120, MSD 150HPS-120

 

 

LAMPING

 

 
Before lamping or re-lamping, make sure that power is turned 
off to the fixture. 
 
To gain access to the lamp compartment, loosen 10 captive 
screws (Item 12) in the removable cover (Item 23).  (Cover 
nearest 1/2 in. NPSI hole).  DO NOT REMOVE BARRIER 
(Item 27).  DO NOT REMOVE THE FIXED COVER (Item 22) 
WHICH HAS THE LAMP SOCKET ATTACHED TO IT. 
 
Screw lamp into socket.  Reinstall removable cover (Item 23) 
and tighten 10 screws (Item 12) to 15 in-lbs.  The fixture can 
be mounted and electric power connected. 

 
1.  Operate fixture ONLY with PROPER lamp.  The internal 
ballast in each fixture is designed to accommodate a specific 
wattage lamp.  See LAMP RECOMMENDATIONS. 
 
2.  If the lamp fails, replace lamp or disconnect primary 
power to fixture within two weeks at the most.  Otherwise, 
permanent damage to electrical components may result from 
high voltage pulses unique to High Pressure Sodium circuits. 
 
3.  Use protective gloves and safety eyeglasses when 
replacing lamps. 
 
If outer glass bulb is broken, turn off lamp and replace it 
promptly to avoid exposure to ultraviolet energy.  Even with 
lamp outer glass enclosure broken, the arc tube may 
continue to fire. 
 
 

LAMP RECOMMENDATIONS

 

 

Fixture Model No. 

 

Wattage 

 

Phoenix 

Part No. 

 

MSD-120-50HPS 

 

50 

 

4211300 

 

MSD-120-70HPS 

 

70 

 

4212600 

 

MSD-120-100HPS 

 

100 

 

4212700 

 

MSD-120-150HPS 

 

150 

 

4212800 

 

 
 

MOUNTING

 

 
Vertical or horizontal mounting kits must be ordered with 
fixture.  Insert one 1/2 inch (12mm) stainless steel bolt 
through the mounting hole provided in the mounting bracket 
and secure with appropriate lock washer and nut on the other 
side of the mounting fixture.  When mounting on a maximum 
1-3/4" OD pole or mast, a 1/4 inch (6mm) stainless steel U-
bolt may be inserted in the holes provided in the bracket and 

the fixture secured with appropriate lock washers and nuts.  
NOTE:  Mounting hardware isn't provided with fixture. 

 

HORIZONTAL MOUNTING-USE KIT NO. 1090170

 

 

VERTICAL MOUNTING-USE KIT NO.  1090160

 

 

 

CAUTION 

 

 