Ver. Phoenix 1.0 _ 01-09-2019
- 10 -
Phoenix Mixer India Pvt. Ltd.
The machine is equipped with a power supply cable having the following specifications:
Length: 8 FT
Size:
14 AWG
The machine shall be connected to a dedicated, grounded circuit, protected by a 15 A circuit breaker.
All wiring shall be in accordance with local codes
Important
:
The power supply cable conductors are color-coded as follows:
GREEN or GREEN/YELLOW
—
GROUND
WHITE or BLUE/BLACK
—
NEUTRAL
BLACK or BROWN/RED
—
LINE
Service safety rules:
1.
Prior to performing any maintenance or inspection of the MELANGE disconnect the power plug
from the electrical outlet in order to ensure that the MELANGE cannot start unexpectedly.
2.
To prevent injuries to personnel ensure that all removable panels are in place and properly
secured except for any necessary inspections or maintenance.
3.
Do not disable or override any of the installed safety features such as the door lock system.
4.
The MELANGE shall be installed in an environment conforming to the appropriate local
regulations. A permit issued by the local authority may be required. Keep the number of paint
cans in the immediate area of the machine to a minimum.
5.
Do not store flammable materials or other materials inside the machine. The area in which the
MELANGE is installed must be kept free of exposed flames, incandescent fixtures or other
devices that might create sparks.
6.
It is recommended that a ventilation system, guaranteed to maintain the concentration of
dangerous vapors around electrical components at less than 30%, be installed.
7.
When the MELANGE is not being used for a period of time (such as at the end of the work day),
ensure that it is empty (no paint can inside), close the door and unplug the power plug from
the outlet.
8.
Ensure that all tools are removed from inside the machine after any maintenance work.
RESIDUAL RISK
Residual risks list for the user:
The MELANGE, and its operating and service instructions, have been developed giving careful
consideration to the safety of the user and service technician. However, there are situations
where risks can be reduced but not eliminated completely.
RISK
PRECAUTION
Injury or crushing during loading and
unloading operations.
Use protective gloves and safety shoes during loading
and unloading operations.
Abrasions and injuries caused by sharp edges
on the cans being used
Use protective gloves during loading and unloading
operations.
Liquid leakage form the cans being used
Thoroughly clean the operator and maintenance areas.
Keep these areas clean.
Summary of Contents for MELANGE
Page 14: ...Ver Phoenix 1 0 _ 01 09 2019 14 Phoenix Mixer India Pvt Ltd LOGIC CARD AS670 101 ME ...
Page 20: ...Ver Phoenix 1 0 _ 01 09 2019 20 Phoenix Mixer India Pvt Ltd 10 SCHEMATIC DIAGRAM ...
Page 21: ...Ver Phoenix 1 0 _ 01 09 2019 21 Phoenix Mixer India Pvt Ltd 11 SPARE PART LIST ...
Page 22: ...Ver Phoenix 1 0 _ 01 09 2019 22 Phoenix Mixer India Pvt Ltd ...