1 Appropriate Use

The measuring device must only be operated within the 
products specifications.
The measuring device must only be used under the 
conditions and for the purposes for which it was designed.
Modification to this device will void the warranty and 
may compromise the accuracy and safe operation of this 
device.

2 Display

3 Operation

The Humiport 05 can be adjusted using the three-way 
“Thumb Wheel” on the left hand side of the device.
Up and down movement of the wheel is used to navigate 
through different menu items on the screen. Items that 
flash intermittently on the screen are items that can be 
adjusted. Pressing the wheel inward will act as a “click” or 
selection of the highlighted item.
When the unit is first turned on, moving the wheel up or 
down will select the upper or lower menus on the screen.

3.1 Three Positions of the Thumb Wheel

Turn up

t  

Turn down

 

Press in the middle position

To switch on:

      (press briefly)

To switch off:

      press for 

approximately 2 seconds 
(No menu activated)

Upper menu:

  

s

 (press briefly), 

select with 

s

, confirm with    . 

  

Lower menu:

 

t

 (press briefly), 

select with 

t

, confirm with    .

Table of Contents

Introduction

 ................................................................1 

1.   Appropriate Use ....................................................2
2.   Display .................................................................2
3.   Operation .............................................................2
 

3.1 Three Positions of the Thumb Wheel .................2

4.   Upper Menu ..........................................................3
5.   Lower Menu ..........................................................3
 

5.1 Single-Point Calibrations of ..............................3 
Temperature and RH

6.   Measuring the Humidity Ratio.................................3
7.   Replacing the Battery ............................................3
8.   Maintenance and Adjustment .................................3
9.   Specifications .......................................................4
10. Warranty/Sensor Repair ........................................5

Serial No. ___________________________

Purchase Date ______/______/_____

Dealer’s Name ___________________________________

Read the operation and maintenance instructions carefully 
before using this the Humiport 05.
Do not measure near live electrical components.
Avoid using in temperature conditions outside of that 
recommended (overheating can lead to their destruction)
Calibration should only be adjusted when used with a 
recommended calibration source or known standard.
Allow approximately 2 minutes for stabilization when taking 
measurements in dramatically different environments.

IMPORTANT WARRANTY INFORMATION BELOW:

The plastic protection cap must be placed on the sensing 
head whenever the meter is not in use. Without this 
protection the sensing elements can be mechanically 
damaged or chemically contaminated.  Meter failures due 
to damage or contamination of the sensing elements are 
not covered under warranty.

Place the meter in the supplied soft case to further protect 
from physical damage and contamination

Upper menu

Hold  MAX  MIN  AVG

888.8

%  WT  CM  m/s °F  °C

Temperature display (Unit 1)

Relative humidity display (Unit 2)

Lower menu

888.8

g/m   °C °F  dp % rH

Unit 12  Cal 12

g/kg  gr/lb          Alt. [ft] 

Summary of Contents for Humiport 05

Page 1: ...tive humidity dew point F or C and the popular grains per lb mixing ratio There is even an altitude input that makes sure the grains calculation is extremely accurate A listing of altitudes by state and some cities is available at www usephoenix com so you can set the meter to your specific area The Phoenix Humiport meters record conditions calculate data and can display MIN minimum MAX maximum AV...

Page 2: ...3 1 Three Positions of the Thumb Wheel 2 4 Upper Menu 3 5 Lower Menu 3 5 1 Single Point Calibrations of 3 Temperature and RH 6 Measuring the Humidity Ratio 3 7 Replacing the Battery 3 8 Maintenance and Adjustment 3 9 Specifications 4 10 Warranty Sensor Repair 5 Serial No ___________________________ Purchase Date ______ ______ _____ Dealer s Name ___________________________________ Read the operati...

Page 3: ... 0 0 to restore the factory calibration CAL2 The lower screen should be showing RH to use this feature With CAL2 single point RH calibration you adjust the value for Sensor 2 on the lower numeric display RH The offset from the factory calibration is shown on the upper display RH Maximum offset adjustment is 10 RH Calibration adjustments must be made at 30 to 95 RH For best full range accuracy cali...

Page 4: ...nsor Phoenix Restoration Therma Stor LLC offers calibration services for all types and makes of hand held temperature and humidity monitors For more information on the Phoenix Calibration service call 1 800 533 7533 9 Specifications Measurement Range RH 5 95 RH Temp 4 to 122 F 20 to 50 C Calculated Values Dew Point F C Humidity Ratio grams Kg dry air grains lb dry air Accuracy RH 3 RH Temp 0 7 F a...

Page 5: ...er immediately upon phone or written request Upon examination by Phoenix if the unit is found to be defective according to the warranty it will be repaired or replaced at no charge If the product is found not to be covered by the warranty the customer will be offered the opportunity to purchase a replacement refurbished unit Phoenix is pleased to offer suggestions on the use of its various product...

Reviews: