QUINT4-INV/24DC/1AC/600VA/USB
108987_en_00
PHOENIX CONTACT
17 / 25
8
Device connection
8.1
Connection parameters
Figure 10
Connection parameters
9
Device connection terminal blocks
9.1
DC input
The supply voltage is connected via the connection terminal
blocks: Input
DC
24
V.
Figure 11
Input voltage connection terminal blocks:
Input
DC
+/-
(1.1,
1.2) and N/
(2.4,
1.3)
The neutral conductor of the AC output is connected to PE
via the pre-installed bridge in terminals 2.4 and 1.3.
Remove the bridge to change the output voltage supply
system configuration.
[mm²]
0.2-4
0.2-4
0.2-4
0.2-1.5
Input DC 1.1...1.2
Output AC 2.1...2.3
Signals 3.1...3.9
N 2.4, PE 1.3
Screw
0.2-6
0.2-6
0.2-6
0.2-1.5
[mm²]
0.2-4
0.2-4
0.2-4
0.2-1.5
[mm²]
[mm²]
0.2-4
0.2-4
0.2-4
0.2-1.5
(Cu)
30-10
30-10
30-10
30-12
8
8
8
8
L
[mm]
0.5-0,6
0.5-0.6
0.5-0.6
0.5-0.6
[Nm]
[lb in]
5-7
5-7
5-7
5-7
AWG
Alarm
DC OK
AC O
K
Out 1
P>Pn
Star
t 230V
Star
t 120V
Remote
SGnd
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
QUINT A
C-INV 600V
A
Ala
rm
3A
C
Lin
k
Po
wer
Sin
gle
Re
dun
dan
cy
AC
O
K
P>Pn / R
emote
L1 (S
lave
)
L1
L1
L2
L3
(M
aste
r)
(Ma
ster)
Soft Star
t
Para
llel P
ort
5.2
L
N
2.1
2.2
2.3
Output A
C 120/230V
N
2.4
1.3
5.1
23
0V
12
0V
+
-
1.1
1.2
Inpu
t D
C 2
4V
N
2.4
1.3
+
-
1.1
1.2
Input DC 24V