PSI-DATA/BASIC-MODEM/RS232 Industrial Modem
102906_01_en
PHOENIX CONTACT
1-5
Conformance With EMC Directive 89/336/EEC
Noise Immunity Test According to EN 61000-6-2
1
Electrostatic discharge (ESD)
EN 61000-4-2
Criterion B
2
8 kV air discharge
6 kV contact discharge
Electromagnetic HF field
Amplitude modulation
Pulse modulation
EN 61000-4-3
Criterion A
3
10 V/m
10 V/m
Fast transients (burst)
Signal
Supply
EN 61000-4-4
Criterion B
Criterion A
2 kV/5 kHz
1 kV/5 kHz
2 kV/5 kHz
Surge current load
Signal
Supply
EN 61000-4-5
Criterion B
1 kV
2 kV
Conducted interference
EN 61000-4-6
Criterion A
10 V
Noise Emission Test According to EN 61000-6-4
Noise emission of housing
EN 55022
Limiting curve B
1
EN 61000 corresponds to IEC 61000
2
Criterion B: Temporary adverse effects on the operating behavior, which the device corrects automatically.
3
Criterion A: Normal operating behavior within the specified limits.